Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.chest.2019.09.015
DC FieldValue
dc.titleThe Search for Optimal Oxygen Saturation Targets in Critically Ill Patients: Observational Data from Large ICU Databases
dc.contributor.authorVAN DEN BOOM, WILLIBRORDUS PETRUS MARIA
dc.contributor.authorHoy, Michael
dc.contributor.authorJAGADISH SANKARAN
dc.contributor.authorLiu, Mengru
dc.contributor.authorChahed, Haroun
dc.contributor.authorFENG MENGLING
dc.contributor.authorSEE KAY CHOONG
dc.date.accessioned2020-10-20T04:34:34Z
dc.date.available2020-10-20T04:34:34Z
dc.date.issued2020-03
dc.identifier.citationVAN DEN BOOM, WILLIBRORDUS PETRUS MARIA, Hoy, Michael, JAGADISH SANKARAN, Liu, Mengru, Chahed, Haroun, FENG MENGLING, SEE KAY CHOONG (2020-03). The Search for Optimal Oxygen Saturation Targets in Critically Ill Patients: Observational Data from Large ICU Databases. CHEST 157 (3) : 566-573. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chest.2019.09.015
dc.identifier.issn00123692
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/177941
dc.description.abstractBackground While low oxygen saturations are generally regarded as deleterious, recent studies in intensive care unit (ICU) patients have shown that a liberal oxygen strategy increases mortality. However, the optimal oxygen saturation target remains unclear. We therefore aimed to elucidate this optimal range with real world data. Methods Replicate retrospective analyses of two electronic medical record databases were done: eICU Collaborative Research Database (eICU-CRD) and the Medical Information Mart for Intensive Care III (MIMIC). Only patients with at least 48 hours of oxygen therapy were included. Nonlinear regression was used to analyze the association between median pulse oximetry-derived oxygen saturation (SpO2) and hospital mortality. We derived an optimal range of SpO2 and analyzed the association between the percentage of time within the optimal range of SpO2 and hospital mortality. All models adjusted for age, body mass index, gender, and SOFA score. Subgroup analyses included ICU types, main diagnosis, and comorbidities. Results We identified 26,723 patients from eICU-CRD and 8,564 patients from MIMIC. The optimal range of SpO2 was 94–98% in both eICU-CRD and MIMIC. The percentage of time patients were within the optimal range of SpO2 was associated with decreased hospital mortality (odds ratio of 80% versus 40% of the measurements within the optimal range: 0.42, 95% CI 0.40 to 0.43, for eICU-CRD and 0.53, 95% CI 0.50 to 0.55 for MIMIC). This association was consistent across subgroup analyses. Conclusions The optimal range of SpO2 was 94–98% and should inform future trials of oxygen therapy.
dc.description.urihttps://doi.org/10.1016/j.chest.2019.09.015
dc.language.isoen
dc.publisherElsevier
dc.rightsAttribution-ShareAlike 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-sa/4.0/
dc.subjectBlood oxygen saturation; electronic medical records; hyperoxemia; intensive care unit; oxygen therapy; pulse oximetry
dc.typeArticle
dc.contributor.departmentDEPT OF BIOLOGICAL SCIENCES
dc.contributor.departmentDEPT OF MEDICINE
dc.contributor.departmentDEPT OF STATISTICS & APPLIED PROBABILITY
dc.contributor.departmentSAW SWEE HOCK SCHOOL OF PUBLIC HEALTH
dc.description.doi10.1016/j.chest.2019.09.015
dc.description.sourcetitleCHEST
dc.description.volume157
dc.description.issue3
dc.description.page566-573
dc.published.statePublished
dc.grant.idR-608-000-199-733
dc.grant.idMOE2016-T2-2-135
dc.grant.idWBS R-608-000-172-133
dc.grant.fundingagencySingapore Ministry of Education Academic Research Fund
dc.grant.fundingagencyNational University of Singapore
Appears in Collections:Elements
Staff Publications

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Accepted_manuscript.pdf5.58 MBAdobe PDF

OPEN

Post-printView/Download

SCOPUSTM   
Citations

16
checked on Apr 15, 2021

Page view(s)

71
checked on Apr 16, 2021

Download(s)

2
checked on Apr 16, 2021

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons