dc.identifier.citationYi Lin, S, Mimi, Y, Ming Tak, C, Kelvin Weng Chiong, F, Hung Chew, W (2015). A study of success rate of miniscrew implants as temporary anchorage devices in Singapore. International Journal of Dentistry 2015 : 294670. ScholarBank@NUS Repository. https://doi.org/10.1155/2015/294670
dc.identifier.issn16878728
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/174147
dc.description.abstractObjective. To find out the success rate of miniscrew implants in the National Dental Centre of Singapore (NDCS) and the impact of patient-related, location-related, and miniscrew implant-related factors. Materials and Methods. Two hundred and eighty-five orthodontic miniscrew implants were examined from NDCS patient records. Eleven variables were analysed to see if there is any association with success. Outcome was measured twice, immediately after surgery prior to orthodontic loading (T1) and 12 months after surgery (T2). The outcome at T2 was assessed 12 months after the miniscrew's insertion date or after its use as a temporary anchorage device has ceased. Results. Overall success rate was 94.7% at T1 and 83.3% at T2. Multivariate analysis revealed only the length of miniscrew implant to be significantly associated with success at both T1 (P = 0.002) and T2 (P = 0.030). Miniscrew implants with lengths of 10-12 mm had the highest success rate (98.0%) compared to other lengths, and this is statistically significant (P = 0.035). At T2, lengths of 10-12 mm had significantly (P = 0.013) higher success rates (93.5%) compared to 6-7 mm (76.7%) and 8 mm (82.1%) miniscrew implants. Conclusion. Multivariate statistical analyses of 11 variables demonstrate that length of miniscrew implant is significant in determining success. © 2015 Song Yi Lin et al.
dc.sourceUnpaywall 20200831
dc.typeArticle
dc.contributor.departmentDUKE-NUS MEDICAL SCHOOL
dc.contributor.departmentDEPT OF DENTISTRY
dc.contributor.departmentDEAN'S OFFICE (MEDICINE)
dc.description.doi10.1155/2015/294670
dc.description.sourcetitleInternational Journal of Dentistry
dc.description.volume2015
dc.description.page294670
Appears in Collections:Elements
Staff Publications

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1155_2015_294670.pdf1.19 MBAdobe PDF

OPEN

NoneView/Download

SCOPUSTM   
Citations

14
checked on Jan 21, 2022

Page view(s)

110
checked on Jan 27, 2022

Download(s)

1
checked on Jan 27, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.