Please use this identifier to cite or link to this item: https://doi.org/10.1039/c6tc04849h
Title: Stretchable heaters with composites of an intrinsically conductive polymer, reduced graphene oxide and an elastomer for wearable thermotherapy
Authors: Zhou, R 
Li, P 
Fan, Z 
Du, D
Ouyang, J 
Keywords: Biocompatibility
Composite films
Conducting polymers
Graphene
Physical therapy
Polymers
Styrene
Tensile strain
Wearable technology
Electrical conductivity
High thermal conductivity
Intrinsically conductive polymers
Low thermal conductivity
Poly-3 ,4-ethylenedioxythiophene
Polystyrene sulfonic acid
Reduced graphene oxides (RGO)
Waterborne polyurethanes
Thermal conductivity
Issue Date: 2017
Citation: Zhou, R, Li, P, Fan, Z, Du, D, Ouyang, J (2017). Stretchable heaters with composites of an intrinsically conductive polymer, reduced graphene oxide and an elastomer for wearable thermotherapy. Journal of Materials Chemistry C 5 (6) : 1544-1551. ScholarBank@NUS Repository. https://doi.org/10.1039/c6tc04849h
Abstract: Thermal therapy is an effective physical treatment method for arthritis, stiff muscles, joint injuries, and injuries to the deep tissue of skin. Stretchable or even wearable electric heaters with uniform heating behavior are regarded as the next-generation electronic devices, which have been extensively studied for the personal thermal management and healthcare purpose. In this work, highly stretchable electrothermal heaters were developed by using composites of intrinsically conductive poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid) (PEDOT:PSS), elastomeric waterborne polyurethane (WPU) and reduced graphene oxide (rGO). rGO was mixed into the PEDOT:PSS/WPU blends to improve the temperature uniformity because rGO has high thermal conductivity while the polymers have very low thermal conductivity. The PEDOT:PSS/WPU/1 wt% rGO composite film exhibits an electrical conductivity of 18.2 S cm?1 and an elongation at break of 530%. The electrothermal performances of the polymer heaters were investigated with respect to the applied voltage, tensile strain, and the voltage on/off cycling process. The heater shows stable heating behavior under repetitive voltage on/off cycles, and the temperature remains almost unchanged under a tensile strain of up to 30%. The devices can be comfortably attached to the skin of humans, for example on the wrist, and they exhibit a uniform and stable heating profile even under mechanical disturbance. Due to their outstanding stretchability, biocompatibility, desirable electrical and thermal conductivities, the WPU/PEDOT:PSS/rGO composites can be used in wearable and long-term thermotherapy applications. © The Royal Society of Chemistry.
Source Title: Journal of Materials Chemistry C
URI: https://scholarbank.nus.edu.sg/handle/10635/173968
ISSN: 20507534
DOI: 10.1039/c6tc04849h
Appears in Collections:Elements
Staff Publications

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1039_c6tc04849h.pdf4.28 MBAdobe PDF

OPEN

NoneView/Download

SCOPUSTM   
Citations

44
checked on Feb 27, 2021

Page view(s)

39
checked on Feb 26, 2021

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.