Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/169437
DC FieldValue
dc.titleSTUDIES OF TRANSVERSE DIFFUSION OF ALKALI IONS IN NOBLE GASES
dc.contributor.authorMARK JAMES HOGAN
dc.date.accessioned2020-06-05T03:44:39Z
dc.date.available2020-06-05T03:44:39Z
dc.date.issued1991
dc.identifier.citationMARK JAMES HOGAN (1991). STUDIES OF TRANSVERSE DIFFUSION OF ALKALI IONS IN NOBLE GASES. ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/169437
dc.description.abstractA new drift-tube apparatus has been developed for measuring DT/K, the ratio of the transverse diffusion coefficient to the mobility of ions in a neutral gas under the influence of an electric field. The main features are the ion current detector, which comprises 65 parallel rods, and an external mechanical multiplexer, which was designed to have extremely low (fA order) leakage currents and noise levels. Unlike with other earlier systems, the need for precise mechanical motion or adjustments of experimental conditions inside the drift tube during data collection has been circumvented. Its design therefore simplifies construction and makes operation less error-prone. Data collection is computer controlled. A value for DT/K can now typically be obtained in less than 20 minutes, which greatly increases the rate at which results can be obtained as well as reduces the chance of unwanted variations in experimental conditions occurring during data collection. Results are estimated to be accurate to within 3%. Room temperature measurements of DT/K were made for Na+ ions in neon and argon, and K+ ions in helium, argon and krypton. Values were obtained at values of E/N, the ratio of the drift tube electric field to neutral gas number density, ranging from 10 to 200 Td for Na+ in neon, 5 to 260 Td for Na+ in argon, 10 to 220 Td for K+ in helium, 10 to 600 Td for K+ in argon, and 5 to 420 Td for K+ in krypton. As a case study of one use of measured values of DT/K, the experimental values are compared with values obtained from Monte Carlo simulations using several proposed interaction potentials as input. The comparisons suggest that none of the potentials examined is a totally accurate representation of the K+-Ar interaction potential.
dc.sourceCCK BATCHLOAD 20200605
dc.typeThesis
dc.contributor.departmentPHYSICS
dc.contributor.supervisorP. P. ONG
dc.description.degreePh.D
dc.description.degreeconferredDOCTOR OF PHILOSOPHY
Appears in Collections:Ph.D Theses (Restricted)

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
b17596798.PDF5.27 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.