Please use this identifier to cite or link to this item: https://doi.org/10.1109/TNSRE.2013.2286955
DC FieldValue
dc.titleSimultaneous neural control of simple reaching and grasping with the modular prosthetic limb using intracranial EEG
dc.contributor.authorFifer, M.S.
dc.contributor.authorHotson, G.
dc.contributor.authorWester, B.A.
dc.contributor.authorMcMullen, D.P.
dc.contributor.authorWang, Y.
dc.contributor.authorJohannes, M.S.
dc.contributor.authorKatyal, K.D.
dc.contributor.authorHelder, J.B.
dc.contributor.authorPara, M.P.
dc.contributor.authorVogelstein, R.J.
dc.contributor.authorAnderson, W.S.
dc.contributor.authorThakor, N.V.
dc.contributor.authorCrone, N.E.
dc.date.accessioned2016-10-19T08:43:52Z
dc.date.available2016-10-19T08:43:52Z
dc.date.issued2014
dc.identifier.citationFifer, M.S., Hotson, G., Wester, B.A., McMullen, D.P., Wang, Y., Johannes, M.S., Katyal, K.D., Helder, J.B., Para, M.P., Vogelstein, R.J., Anderson, W.S., Thakor, N.V., Crone, N.E. (2014). Simultaneous neural control of simple reaching and grasping with the modular prosthetic limb using intracranial EEG. IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (3) : 695-705. ScholarBank@NUS Repository. https://doi.org/10.1109/TNSRE.2013.2286955
dc.identifier.issn15344320
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/128670
dc.description.abstractIntracranial electroencephalographic (iEEG) signals from two human subjects were used to achieve simultaneous neural control of reaching and grasping movements with the Johns Hopkins University Applied Physics Lab (JHU/APL) Modular Prosthetic Limb (MPL), a dexterous robotic prosthetic arm. We performed functional mapping of high gamma activity while the subject made reaching and grasping movements to identify task-selective electrodes. Independent, online control of reaching and grasping was then achieved using high gamma activity from a small subset of electrodes with a model trained on short blocks of reaching and grasping with no further adaptation. Classification accuracy did not decline (p < 0.05, one-way ANOVA) over three blocks of testing in either subject. Mean classification accuracy during independently executed overt reach and grasp movements for (Subject 1, Subject 2) were (0.85, 0.81) and (0.80, 0.96), respectively, and during simultaneous execution they were (0.83, 0.88) and (0.58, 0.88), respectively. Our models leveraged knowledge of the subject's individual functional neuroanatomy for reaching and grasping movements, allowing rapid acquisition of control in a time-sensitive clinical setting. We demonstrate the potential feasibility of verifying functionally meaningful iEEG-based control of the MPL prior to chronic implantation, during which additional capabilities of the MPL might be exploited with further training. © 2014 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/TNSRE.2013.2286955
dc.sourceScopus
dc.subjectBrain-machine interface (BMI)
dc.subjectelectrocorticography
dc.subjectfunctional mapping
dc.subjecthigh gamma
dc.subjectupper limb prosthesis
dc.typeArticle
dc.contributor.departmentELECTRICAL ENGINEERING
dc.description.doi10.1109/TNSRE.2013.2286955
dc.description.sourcetitleIEEE Transactions on Neural Systems and Rehabilitation Engineering
dc.description.volume22
dc.description.issue3
dc.description.page695-705
dc.description.codenITNSB
dc.identifier.isiut000342079300028
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.