Title: Experimental investigation of the human convective boundary layer in a quiescent indoor environment
Authors: Licina, D.
Pantelic, J.
Melikov, A.
Sekhar, C. 
Tham, K.W. 
Keywords: Body posture
Clothing insulation/design
Convective boundary layer
Pseudo color visualization
Temperature
Thermal manikin
Issue Date: May-2014
Citation: Licina, D., Pantelic, J., Melikov, A., Sekhar, C., Tham, K.W. (2014-05). Experimental investigation of the human convective boundary layer in a quiescent indoor environment. Building and Environment 75 : 79-91. ScholarBank@NUS Repository. https://doi.org/10.1016/j.buildenv.2014.01.016
Abstract: This study aims to characterize human convective boundary layer (CBL) in a quiescent indoor environment. The study has two objectives: first, to characterize the velocity field around the thermal manikin under two ambient temperatures and body postures; and secondly, the influence of clothing insulation/design, chair design, table positioning and seated body inclination on airflow characteristics in the breathing zone of a sitting manikin is examined. The increase of the ambient temperature from 20 to 26°C widens the CBL flow in front of the sitting manikin but do not influence the shape of the CBL in front of the standing manikin. The same temperature increase causes the reduction of the CBL mean peak velocity from 0.24 to 0.16m/s in front of the sitting manikin. Dressing the nude manikin with thin-tight clothing ensemble reduces the peak velocity in the breathing zone from 0.205m/s by 17%, and by 40% for thick-loose ensemble. Removing the wig increases the peak velocity from 0.17 to 0.187m/s. Clothing and chair design have a minor influence on the velocity profile beyond 5cm distance from the body. Closing the gap between the table and the manikin reduces the peak velocity from 0.17 to 0.111m/s. Manikin leaned backwards induces the peak velocity of 0.185m/s, which is 45% above the case when manikin is leaned forward. PIV measurements complemented with Pseudo color visualization (PCV) technique provide a good synergy between quantitative and qualitative airflow characteristics and can be adequately employed for the CBL investigation. © 2014 Elsevier Ltd.
Source Title: Building and Environment
URI: http://scholarbank.nus.edu.sg/handle/10635/113955
ISSN: 03601323
DOI: 10.1016/j.buildenv.2014.01.016
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.