Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.gie.2010.04.009
DC FieldValue
dc.titleEndoscopic submucosal dissection of gastric lesions by using a Master and Slave Transluminal Endoscopic Robot (MASTER)
dc.contributor.authorHo, K.-Y.
dc.contributor.authorPhee, S.J.
dc.contributor.authorShabbir, A.
dc.contributor.authorLow, S.C.
dc.contributor.authorHuynh, V.A.
dc.contributor.authorKencana, A.P.
dc.contributor.authorYang, K.
dc.contributor.authorLomanto, D.
dc.contributor.authorSo, B.Y.J.
dc.contributor.authorWong, Y.Y.J.
dc.contributor.authorChung, S.C.S.
dc.date.accessioned2014-12-01T06:54:44Z
dc.date.available2014-12-01T06:54:44Z
dc.date.issued2010-09
dc.identifier.citationHo, K.-Y., Phee, S.J., Shabbir, A., Low, S.C., Huynh, V.A., Kencana, A.P., Yang, K., Lomanto, D., So, B.Y.J., Wong, Y.Y.J., Chung, S.C.S. (2010-09). Endoscopic submucosal dissection of gastric lesions by using a Master and Slave Transluminal Endoscopic Robot (MASTER). Gastrointestinal Endoscopy 72 (3) : 593-599. ScholarBank@NUS Repository. https://doi.org/10.1016/j.gie.2010.04.009
dc.identifier.issn00165107
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/113459
dc.description.abstractBackground: Performing endoscopic submucosal dissection (ESD) by using standard endoscopy platforms is technically challenging because of the equipment's lack of dexterity. Objective: To explore the feasibility of using the Master and Slave Transluminal Endoscopic Robot (MASTER), a novel robotics-enhanced endosurgical system, to perform ESD. Design: ESD was performed on simulated gastric lesions in 5 Erlangen porcine stomach models (ex vivo) and 5 live pigs (in vivo). Performance of ESD by using the MASTER was compared with that using the insulation-tipped (IT) diathermic knife. Setting: SMART Laboratory, Advance Surgical Training Centre, National University Hospital, Singapore. Subjects: Five Erlangen porcine stomach models and 5 pigs, 5 to 7 months old, each weighing about 35 kg. Interventions: ESD. Main Outcome Measurements: Lesion resection time, grasper and hook efficacy grade, completeness of resection, and presence of procedure-related perforation. Results: In the Erlangen stomach models, 15 simulated lesions from the cardia, antrum, and body were removed en bloc (mean dimension, 37.4 × 26.5 mm) by electrocautery excision using the MASTER. The mean ESD time was 23.9 minutes (range 7-48 minutes). There was no difference in the dissection times of lesions at different locations (P = .449). In the live pigs, the MASTER took a mean of 16.2 minutes (range 3-29 minutes) to complete the ESD of 5 gastric lesions, whereas the IT diathermic knife took 18.6 minutes (range 9-34 minutes). There was no significant difference in the times taken (P = .708). All lesions were excised en bloc; the mean dimensions of lesions resected by the MASTER and the IT diathermic knife were 37.2 × 30.1 mm and 32.78 × 25.6 mm, respectively. The MASTER exhibited good grasping and cutting efficiency throughout. Surgical maneuvers were achieved with ease and precision. There was no incidence of excessive bleeding or stomach wall perforation. Limitations: Exploratory study with limited sample size. Conclusions: Performing ESD by using the MASTER is feasible. © 2010 American Society for Gastrointestinal Endoscopy.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.gie.2010.04.009
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentDEAN'S OFFICE (MEDICINE)
dc.description.doi10.1016/j.gie.2010.04.009
dc.description.sourcetitleGastrointestinal Endoscopy
dc.description.volume72
dc.description.issue3
dc.description.page593-599
dc.description.codenGAENB
dc.identifier.isiut000281672800022
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.