Please use this identifier to cite or link to this item:
https://doi.org/10.1097/ICO.0b013e31828321f8
DC Field | Value | |
---|---|---|
dc.title | Descemet stripping automated endothelial keratoplasty in complex eyes: Results with a donor insertion device | |
dc.contributor.author | Khor, W.-B. | |
dc.contributor.author | Teo, K.Y. | |
dc.contributor.author | Mehta, J.S. | |
dc.contributor.author | Tan, D.T.-H. | |
dc.date.accessioned | 2014-11-26T08:27:34Z | |
dc.date.available | 2014-11-26T08:27:34Z | |
dc.date.issued | 2013-08 | |
dc.identifier.citation | Khor, W.-B., Teo, K.Y., Mehta, J.S., Tan, D.T.-H. (2013-08). Descemet stripping automated endothelial keratoplasty in complex eyes: Results with a donor insertion device. Cornea 32 (8) : 1063-1068. ScholarBank@NUS Repository. https://doi.org/10.1097/ICO.0b013e31828321f8 | |
dc.identifier.issn | 02773740 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/110014 | |
dc.description.abstract | PURPOSE: Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with complex anterior segment pathology or previous intraocular surgery is at risk of surgical complications and graft failure. We evaluated the use of the EndoGlide donor insertion device for DSAEK in these complex cases. METHODS: This was a retrospective interventional series of 45 consecutive eyes with endothelial dysfunction and higher risk ocular comorbidities that underwent DSAEK with the EndoGlide. We included eyes with aphakia, glaucoma surgery, prior vitrectomy, anterior chamber intraocular lenses, failed cornea grafts, and primary angle closure glaucoma. Demographic and clinical details, intraoperative and postoperative complications, and postoperative graft clarity, and endothelial cell density (ECD) loss were documented. RESULTS: The average age was 62 years (range, 16-88 years), and the majority were Chinese (n = 28). The commonest risk factors identified were previous trabeculectomy (n = 13) and failed penetrating keratoplasty (n = 12). Preoperative donor ECD averaged 2790 ± 230 cells per square millimeter and modal graft diameter was 9.0 mm (range, 7.75-9.75 mm). One eye (2.2%) had primary graft failure, and 3 eyes (6.7%) had graft dislocation. Another 3 eyes suffered late graft failure within the first year and 2 were in eyes with an anterior chamber intraocular lenses. At 6 months, the mean ECD was 2363 + 242 cells/mm and the mean ECD loss was 17.9% (n = 16). By 12 months, the mean ECD was 2098 + 462 cells/mm and the mean ECD loss was 27.0% (n = 20). CONCLUSIONS: Donor insertion with this device can help address inherent intraoperative challenges and minimize endothelial cell damage during DSAEK in complex cases. Copyright © 2013 by Lippincott Williams & Wilkins. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1097/ICO.0b013e31828321f8 | |
dc.source | Scopus | |
dc.subject | donor insertion | |
dc.subject | DSAEK | |
dc.subject | EndoGlide | |
dc.subject | endothelial cell count | |
dc.subject | graft survival | |
dc.type | Article | |
dc.contributor.department | DUKE-NUS GRADUATE MEDICAL SCHOOL S'PORE | |
dc.description.doi | 10.1097/ICO.0b013e31828321f8 | |
dc.description.sourcetitle | Cornea | |
dc.description.volume | 32 | |
dc.description.issue | 8 | |
dc.description.page | 1063-1068 | |
dc.description.coden | CORND | |
dc.identifier.isiut | 000322114000004 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.