Please use this identifier to cite or link to this item:
https://doi.org/10.1021/la304394s
DC Field | Value | |
---|---|---|
dc.title | Surface-scribed transparency-based microplates | |
dc.contributor.author | Li, X.Y. | |
dc.contributor.author | Cheong, B.H.-P. | |
dc.contributor.author | Somers, A. | |
dc.contributor.author | Liew, O.W. | |
dc.contributor.author | Ng, T.W. | |
dc.date.accessioned | 2014-11-26T07:48:41Z | |
dc.date.available | 2014-11-26T07:48:41Z | |
dc.date.issued | 2013-01-15 | |
dc.identifier.citation | Li, X.Y., Cheong, B.H.-P., Somers, A., Liew, O.W., Ng, T.W. (2013-01-15). Surface-scribed transparency-based microplates. Langmuir 29 (2) : 849-855. ScholarBank@NUS Repository. https://doi.org/10.1021/la304394s | |
dc.identifier.issn | 07437463 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/109677 | |
dc.description.abstract | Transparency sheets, which are normally associated with use on overhead projectors, offer lowered costs and high amenability for optical diagnostics in microplate instrumentation. An alternative microplate design in which circles are scribed on the surface of the transparency to create the boundaries to hold the drop in place is investigated here. The 3D profile of the scribed regions obtained optically showed strong likelihood of affecting three-phase contact line interactions. During dispensation, the contact angle (≈95) was larger than the drop advancing state (≈80) due to a period of nonadhesion, where the contact angle later reduced to the drop advancing state followed by increase in the liquid area coverage on the substrate. It was established that 50 μL was needed to fill the well fully, and the maximum volume retainable before breaching was 190 μL. While the tilt angle needed for displacement reduced significantly from 50 to 95 μL, this was markedly better than nonscribed surfaces, where tilt angles always had to be kept to within 30. It was found that there was greater ability to fill the well with smaller volumes with dispensation at the center. This was attributed to the growing contact line not meeting the scribed edge in parallel if liquid was dispensed closer to it, wherein pinning reduction in some directions permitted liquid travel along the scribed edge to undergo contact angle hysteresis. Fluorescence measurements conducted showed no performance compromise when using scribed transparency microplates over standard microplates. © 2012 American Chemical Society. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1021/la304394s | |
dc.source | Scopus | |
dc.type | Article | |
dc.contributor.department | MEDICINE | |
dc.description.doi | 10.1021/la304394s | |
dc.description.sourcetitle | Langmuir | |
dc.description.volume | 29 | |
dc.description.issue | 2 | |
dc.description.page | 849-855 | |
dc.description.coden | LANGD | |
dc.identifier.isiut | 000313667300039 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
SCOPUSTM
Citations
20
checked on Feb 3, 2023
WEB OF SCIENCETM
Citations
23
checked on Feb 3, 2023
Page view(s)
192
checked on Feb 2, 2023
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.