Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.ophtha.2012.01.011
DC FieldValue
dc.titleDeterminants of anterior chamber depth: The singapore chinese eye study
dc.contributor.authorSng, C.C.
dc.contributor.authorFoo, L.-L.
dc.contributor.authorCheng, C.-Y.
dc.contributor.authorAllen Jr., J.C.
dc.contributor.authorHe, M.
dc.contributor.authorKrishnaswamy, G.
dc.contributor.authorNongpiur, M.E.
dc.contributor.authorFriedman, D.S.
dc.contributor.authorWong, T.Y.
dc.contributor.authorAung, T.
dc.date.accessioned2014-11-25T09:06:05Z
dc.date.available2014-11-25T09:06:05Z
dc.date.issued2012-06
dc.identifier.citationSng, C.C., Foo, L.-L., Cheng, C.-Y., Allen Jr., J.C., He, M., Krishnaswamy, G., Nongpiur, M.E., Friedman, D.S., Wong, T.Y., Aung, T. (2012-06). Determinants of anterior chamber depth: The singapore chinese eye study. Ophthalmology 119 (6) : 1143-1150. ScholarBank@NUS Repository. https://doi.org/10.1016/j.ophtha.2012.01.011
dc.identifier.issn01616420
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/108196
dc.description.abstractPurpose: Recent advances in anterior segment imaging have enabled the measurement of novel ocular biometric parameters, such as lens vault (LV), posterior corneal arc length (PCAL), and iris area. The aims of this study were to identify the determinants of anterior chamber depth (ACD) and to ascertain the relative importance of these determinants in Chinese persons in Singapore. Design: Population-based, cross-sectional study. Participants: One thousand sixty Chinese participants recruited from the Singapore Chinese Eye Study. Methods: All subjects underwent AS optical coherence tomography (OCT; Carl Zeiss Meditec, Dublin, CA). Customized software (Zhongshan Angle Assessment Program, Guangzhou, China) was used to measure the AS-OCT parameters. Anterior chamber depth was determined using IOLMaster (Carl Zeiss Meditec). Univariate and multivariate regression analyses were performed to assess the association between ACD with ocular biometric and systemic parameters. A stepwise selection algorithm was used to identify sequentially the contribution of each independent variable. Main Outcome Measures: Anterior chamber depth and ocular biometric parameters. Results: The mean age (±standard deviation) of participants was 56.9±8.57 years and 50.5% were men. The mean ACD was 3.24±0.35 mm. The strongest determinants of ACD were LV (R 2 = 0.582; P
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.ophtha.2012.01.011
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentOPHTHALMOLOGY
dc.contributor.departmentSAW SWEE HOCK SCHOOL OF PUBLIC HEALTH
dc.description.doi10.1016/j.ophtha.2012.01.011
dc.description.sourcetitleOphthalmology
dc.description.volume119
dc.description.issue6
dc.description.page1143-1150
dc.description.codenOPHTD
dc.identifier.isiut000304717100009
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.