Please use this identifier to cite or link to this item: https://doi.org/10.1002/rcm.4926
DC FieldValue
dc.titleUltra-pressure liquid chromatography/tandem mass spectrometry targeted profiling of arachidonic acid and eicosanoids in human colorectal cancer
dc.contributor.authorMal, M.
dc.contributor.authorKoh, P.K.
dc.contributor.authorCheah, P.Y.
dc.contributor.authorChan, E.C.Y.
dc.date.accessioned2014-10-29T02:00:39Z
dc.date.available2014-10-29T02:00:39Z
dc.date.issued2011-03
dc.identifier.citationMal, M., Koh, P.K., Cheah, P.Y., Chan, E.C.Y. (2011-03). Ultra-pressure liquid chromatography/tandem mass spectrometry targeted profiling of arachidonic acid and eicosanoids in human colorectal cancer. Rapid Communications in Mass Spectrometry 25 (6) : 755-764. ScholarBank@NUS Repository. https://doi.org/10.1002/rcm.4926
dc.identifier.issn09514198
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/106479
dc.description.abstractCumulative evidence shows that eicosanoids such as prostaglandins, leukotrienes, thromboxanes and hydroxy eicosatetraenoic acids play an important role in associating inflammation with human colorectal cancer (CRC). In this study an ultra-pressure liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and validated for the targeted profiling of eight relevant eicosanoids and the major metabolic precursor, arachidonic acid (AA), in human colon. Multiple reaction monitoring (MRM) experiments were performed in negative electrospray ionization mode. The metabolites were separated using a C18 column consisting of 1.7 μm ethylene-bridged hybrid particles (100 x 2.1 mm i.d.) and gradient elution (50 to 95% of solvent B) with a mobile phase comprising water (0.1% formic acid) [solvent A] and acetonitrile (0.1% formic acid) [solvent B] at a flow rate of 0.4 mL/min. The analysis time for each sample was 5.5 min. Our UPLC/MS/MS method demonstrated satisfactory validation results in terms of selectivity, sensitivity, matrix effect, linearity, extraction efficiency, intra- and inter-day precision, accuracy and autosampler stability. The method was applied for the clinical profiling of matched pairs of cancerous and normal colon mucosae obtained from eight colorectal cancer patients. Endogenous levels of AA and selected eicosanoids such as prostaglandin E2 (PGE2), prostacyclin (PGI2) [assayed as its stable hydrolytic product 6-keto- prostaglandin1α (6-k. PGF1α)] and 12-hydroxy-5Z,8Z,10E,14Z-eicosatetraenoic acid (12-HETE) were found to be significantly different (p
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1002/rcm.4926
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentPHARMACY
dc.description.doi10.1002/rcm.4926
dc.description.sourcetitleRapid Communications in Mass Spectrometry
dc.description.volume25
dc.description.issue6
dc.description.page755-764
dc.description.codenRCMSE
dc.identifier.isiut000287596300010
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.