Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/105637
DC FieldValue
dc.titleAn expedient assay for determination of gemcitabine and its metabolite in human plasma using isocratic ion-pair reversed-phase high-performance liquid chromatography
dc.contributor.authorWang, L.-Z.
dc.contributor.authorGoh, B.-C.
dc.contributor.authorLee, H.-S.
dc.contributor.authorNoordhuis, P.
dc.contributor.authorPeters, G.J.
dc.date.accessioned2014-10-29T01:48:24Z
dc.date.available2014-10-29T01:48:24Z
dc.date.issued2003-10
dc.identifier.citationWang, L.-Z., Goh, B.-C., Lee, H.-S., Noordhuis, P., Peters, G.J. (2003-10). An expedient assay for determination of gemcitabine and its metabolite in human plasma using isocratic ion-pair reversed-phase high-performance liquid chromatography. Therapeutic Drug Monitoring 25 (5) : 552-557. ScholarBank@NUS Repository.
dc.identifier.issn01634356
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/105637
dc.description.abstractAn expedient method is presented for determination in human plasma of gemcitabine and its metabolite 2′,2′-difluorodeoxyuridine (dFdU) by ion-pair reversed-phase HPLC. Samples were simply prepared by protein precipitation. Separation was processed on a Thermo Hypersil column (250 × 4.6 mm, 5 μm Hypersil® BDS C18) with UV detection at 272 nm. The mobile phase consisted of 17% methanol and 83% phosphate buffer (20 mM, pH 3.1) containing 10 mM sodium 1-heptanesulfonate with a flow rate of 0.8 mL/min. The lower limit of quantification (LLOQ) of gemcitabine was 0.08 μg/mL with linear response over the range 0.08-20.0 μg/mL, and LLOQ of dFdU was 0.1 μg/mL with linear response over the range 0.1-50.0 μg/mL. Assay accuracy for both compounds was within ± 4%. The coefficient of variation (CV %) for intra- and interday precision for both compounds was
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1097/00007691-200310000-00003
dc.sourceScopus
dc.subject2′,2′-difluorodeoxyuridine
dc.subjectGemcitabine
dc.subjectHPLC
dc.subjectIon-pair
dc.subjectPlasma
dc.typeArticle
dc.contributor.departmentPHARMACY
dc.description.sourcetitleTherapeutic Drug Monitoring
dc.description.volume25
dc.description.issue5
dc.description.page552-557
dc.description.codenTDMOD
dc.identifier.isiut000185579300003
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

25
checked on Mar 6, 2018

WEB OF SCIENCETM
Citations

17
checked on Dec 31, 2018

Page view(s)

102
checked on May 17, 2021

Google ScholarTM

Check