Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.aca.2012.03.016
DC FieldValue
dc.titleSimultaneous determination of ultraviolet filters in aqueous samples by plunger-in-needle solid-phase microextraction with graphene-based sol-gel coating as sorbent coupled with gas chromatography-mass spectrometry
dc.contributor.authorZhang, H.
dc.contributor.authorLee, H.K.
dc.date.accessioned2014-10-16T08:40:19Z
dc.date.available2014-10-16T08:40:19Z
dc.date.issued2012-09-12
dc.identifier.citationZhang, H., Lee, H.K. (2012-09-12). Simultaneous determination of ultraviolet filters in aqueous samples by plunger-in-needle solid-phase microextraction with graphene-based sol-gel coating as sorbent coupled with gas chromatography-mass spectrometry. Analytica Chimica Acta 742 : 67-73. ScholarBank@NUS Repository. https://doi.org/10.1016/j.aca.2012.03.016
dc.identifier.issn00032670
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/94809
dc.description.abstractA simple, sensitive and selective method for the simultaneous determination of five ultraviolet (UV) filters: benzophenone, octyl salicylate, homosalate, 3-(4-methylbenzylidene) camphor, 2-hydroxy-4-methoxybenzophenone in aqueous samples was developed. The analytes were extracted by plunger-in-needle solid-phase microextraction with graphene as sorbent, then silylated on-fiber with N-methyl-N-(trimethylsilyl)trifluoroacetamide, and analyzed by gas chromatography-mass spectrometry. Factors affecting the performance of extraction and derivatization steps were thoroughly evaluated. For the optimization of extraction conditions, six relevant factors (parameters) were investigated, including sample pH, salt concentration, extraction time, extraction temperature, stirring speed and sampling mode. In the first stage, a two-level orthogonal array design OA8 (27) matrix was employed to study the effect of six factors. Based on the results of the first stage, three factors were selected for further optimization with a univariant approach during the second stage. Under the final optimized conditions, the method limits of detection for the five UV filters were determined to be in the range of 0.5 and 6.8ngL-1 (at a signal/noise ratio of 3) and the precision (% relative standard deviation, n=5) was 0.8-5.6% at a concentration level of 1μgL-1. The linearities for different analytes were 10-10,000 or 1-5000ngL-1. The coefficients of determination for the calibration curves were all greater than 0.994. Finally, the proposed method was successfully applied to the extraction and determination of the UV filters in river water samples. © 2012 Elsevier B.V.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.aca.2012.03.016
dc.sourceScopus
dc.subjectDerivatization
dc.subjectGas chromatography-mass spectrometry
dc.subjectGraphene
dc.subjectPlunger-in-needle solid-phase microextraction
dc.subjectUltraviolet filters
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/j.aca.2012.03.016
dc.description.sourcetitleAnalytica Chimica Acta
dc.description.volume742
dc.description.page67-73
dc.description.codenACACA
dc.identifier.isiut000307919600011
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.