Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.watres.2008.11.039
DC FieldValue
dc.titleDetermination of virus abundance, diversity and distribution in a municipal wastewater treatment plant
dc.contributor.authorWu, Q.
dc.contributor.authorLiu, W.-T.
dc.date.accessioned2014-10-08T08:32:04Z
dc.date.available2014-10-08T08:32:04Z
dc.date.issued2009-03
dc.identifier.citationWu, Q., Liu, W.-T. (2009-03). Determination of virus abundance, diversity and distribution in a municipal wastewater treatment plant. Water Research 43 (4) : 1101-1109. ScholarBank@NUS Repository. https://doi.org/10.1016/j.watres.2008.11.039
dc.identifier.issn00431354
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/87483
dc.description.abstractProcedures to extract and count sludge viruses-like particles from municipal sewage treatment plant were optimized by epifluorescence microscopy using SYBR Green I as a stain. The highest indigenous virus yields from the bulk of the anaerobic digestion sludge and influent (solid) were obtained by utilizing 10 mM sodium pyrophosphate as eluant solution with vortex and 1 min of sonication. The use of 1× phosphate buffered saline as eluant with vortex and 1 min of sonication yields highest indigenous virus from activated sludge. The efficiency of extracting indigenous viruses by sodium pyrophosphate-ultrasound treatment was about 62% of the extractable virus particles from activated sludge and 87% for anaerobic digestion sludge, respectively. Samples treated with DNase had decreased, but not significant, virus counts, suggesting a minor effect of extracellular DNA on virus count. Following the optimized procedure, we investigated the abundance and diversity of virus particles in the wastewater stream of a municipal treatment plant. The concentrations of virus particles ranged from 0.28 × 109 ml-1 to 27.04 × 109 ml-1. Transmission electron microscopy (TEM) showed a high variety of virus morphotypes in sludge. Pulsed-field gel electrophoresis (PFGE) revealed a diverse and dynamic viral community in different stages of the system with genome sizes ranging from 33 kb to >350 kb with most of the viral DNA in the 30-80 kb and 200-350 kb size ranges. Collectively, our study suggested that indigenous viruses are abundant and dynamic in the municipal wastewater treatment system and may play an important role in functioning of the system. © 2008 Elsevier Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.watres.2008.11.039
dc.sourceScopus
dc.subjectAbundance
dc.subjectDiversity
dc.subjectMunicipal wastewater treatment plant
dc.subjectSludge
dc.subjectVirus particle
dc.typeArticle
dc.contributor.departmentDIVISION OF ENVIRONMENTAL SCIENCE & ENGG
dc.description.doi10.1016/j.watres.2008.11.039
dc.description.sourcetitleWater Research
dc.description.volume43
dc.description.issue4
dc.description.page1101-1109
dc.description.codenWATRA
dc.identifier.isiut000264328600024
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.