Please use this identifier to cite or link to this item: https://doi.org/10.1115/1.4001161
Title: Design of a mechanical larynx with agarose as a soft tissue substitute for vocal fold applications
Authors: Choo, J.Q.
Lau, D.P.C.
Chui, C.K. 
Yang, T.
Chng, C.B.
Teoh, S.H. 
Keywords: Agarose
Mechanical larynx
Surgical experimentation
Vocal fold substitute
Issue Date: Jun-2010
Citation: Choo, J.Q., Lau, D.P.C., Chui, C.K., Yang, T., Chng, C.B., Teoh, S.H. (2010-06). Design of a mechanical larynx with agarose as a soft tissue substitute for vocal fold applications. Journal of Biomechanical Engineering 132 (6) : -. ScholarBank@NUS Repository. https://doi.org/10.1115/1.4001161
Abstract: Mechanical and computational models consisting of flow channels with convergent and oscillating constrictions have been applied to study the dynamics of human vocal fold vibration. To the best of our knowledge, no mechanical model has been studied using a material substitute with similar physical properties to the human vocal fold for surgical experimentation. In this study, we design and develop a mechanical larynx with agarose as a vocal fold substitute, and assess its suitability for surgical experimentation. Agarose is selected as a substitute for the vocal fold as it exhibits similar nonlinear hyperelastic characteristics to biological soft tissue. Through uniaxial compression and extension tests, we determined that agarose of 0.375% concentration most closely resembles the vocal fold mucosa and ligament of a 20-year old male for small tensile strain with an R2 value of 0.9634 and root mean square error of 344.05 ± 39.84 Pa. Incisions of 10 mm lengthwise and 3 mm in depth were created parallel to the medial edge on the superior surface of agar phantom. These were subjected to vibrations of 80, 130, and 180 Hz, at constant amplitude of 0.9 mm over a period of 10 min each in the mechanical larynx model. Lateral expansion of the incision was observed to be most significant for the lower frequency of 80 Hz. This model serves as a basis for future assessments of wound closure techniques during microsurgery to the vocal fold. Copyright © 2010 by ASME.
Source Title: Journal of Biomechanical Engineering
URI: http://scholarbank.nus.edu.sg/handle/10635/84964
ISSN: 01480731
DOI: 10.1115/1.4001161
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

4
checked on Jul 12, 2018

WEB OF SCIENCETM
Citations

4
checked on Jun 5, 2018

Page view(s)

37
checked on Jun 29, 2018

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.