Title: Comparison of flexural properties of composite restoratives using the iso and mini-flexural tests
Authors: Yap, A.U.J. 
Teoh, S.H. 
Keywords: Composites
Flexural
Modulus
Strength
Issue Date: 1-Feb-2003
Citation: Yap, A.U.J., Teoh, S.H. (2003-02-01). Comparison of flexural properties of composite restoratives using the iso and mini-flexural tests. Journal of Oral Rehabilitation 30 (2) : 171-177. ScholarBank@NUS Repository. https://doi.org/10.1046/j.1365-2842.2003.01004.x
Abstract: The purpose of this study was to investigate the flexural properties (flexural strength and flexural modulus) of four commercial composite restoratives (Silux Plus, Z100, Ariston and Surefil) using the ISO 4049 flexural test (IFT) and a mini-flexural test (MFT). Both tests involved the use of three-point loading and the same fixture. The difference between the tests was in the length of the composites specimens and the distance between the supports [20 mm (IFT) and 10 mm (MFT)]. Six specimens were made for each material and flexural test. Test specimens [25 x 2 x 2 mm (IFT) and 12 x 2 x 2 mm (MFT)] were fabricated according to manufacturers' recommendations. After light-polymerization, the specimens were stored in distilled water at 37°C for 24 h. The specimens were subsequently blotted dry, measured and subjected to flexural testing using an Instron Universal Testing Machine with a crosshead speed of 0.75 mm min-1. Data was analysed using ANOVA/Scheffe's, paired samples test (P < 0.05) and Pearson's correlation (P < 0.01). For both IFT and MFT, results of statistical analysis of flexural strength were identical. Silux had significantly lower flexural strength compared with the other composites and the flexural strength of Ariston was significantly lower than Z100 and Surefil. For IFT, the flexural modulus of Z100 was significantly higher than Silux, Ariston and Surefil while for MFT, Silux had significantly lower modulus compared with Z100, Ariston and Surefil. A significant, strong and positive correlation (r = 0.95) was observed for flexural strength between IFT and MFT. Correlation for flexural modulus was also significant and positive but was weaker (r = 0.53). As MFT has the advantage of ease of specimen fabrication and is more clinically realistic, it is suggested for the testing of composite restoratives. Clinical relevance The mini-flexural test may be better than the ISO flexural test for screening of composite restoratives for clinical applications.
Source Title: Journal of Oral Rehabilitation
URI: http://scholarbank.nus.edu.sg/handle/10635/84926
ISSN: 0305182X
DOI: 10.1046/j.1365-2842.2003.01004.x
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.