Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.cej.2009.02.015
DC FieldValue
dc.titleA numerical study on premixed micro-combustion of CH4-air mixture: Effects of combustor size, geometry and boundary conditions on flame temperature
dc.contributor.authorLi, J.
dc.contributor.authorChou, S.K.
dc.contributor.authorYang, W.M.
dc.contributor.authorLi, Z.W.
dc.date.accessioned2014-10-07T09:00:32Z
dc.date.available2014-10-07T09:00:32Z
dc.date.issued2009-07-15
dc.identifier.citationLi, J., Chou, S.K., Yang, W.M., Li, Z.W. (2009-07-15). A numerical study on premixed micro-combustion of CH4-air mixture: Effects of combustor size, geometry and boundary conditions on flame temperature. Chemical Engineering Journal 150 (1) : 213-222. ScholarBank@NUS Repository. https://doi.org/10.1016/j.cej.2009.02.015
dc.identifier.issn13858947
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/84807
dc.description.abstractA numerical study on CH4-air premixed combustion in micro-combustors was undertaken by solving the 2D governing equations. The effects of combustor size and geometry, inlet velocity profile and slip-wall boundary condition on the flame temperature were investigated. The simulation results showed that a larger combustor (d = 2 mm) gives higher flame temperature only when the flow velocity is below a certain level. With regard to the combustor geometry, a 2D planar channel (H = 1 mm) represents higher flame temperature than a cylindrical tube with d = 2 mm (equal hydrodynamic diameter), over the velocity range covered by the present study. In addition, it was noted that the flame temperatures in the cylindrical tube and 2D planar channel are quite close when H = 0.65d is satisfied. The fully developed velocity profile applied at the inlet plane was found to have the flames anchored further from the entrance than the uniform profile, but no remarkable difference in terms of flame temperature (≤3 K) was observed. A simple analysis of the competing time scales (axial convection and radial diffusion) was presented to address the difference of flame structure between the methane-air and hydrogen-air mixtures. Finally, it was shown that in a combustor with d = 1 mm the effects of slip-wall boundary are negligible, compared to the bulk velocity and gases temperature. © 2009 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.cej.2009.02.015
dc.sourceScopus
dc.subjectBoundary conditions
dc.subjectFlame temperature
dc.subjectMethane-air
dc.subjectMicro-combustion
dc.subjectNumerical simulation
dc.typeArticle
dc.contributor.departmentSINGAPORE SYNCHROTRON LIGHT SOURCE
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.cej.2009.02.015
dc.description.sourcetitleChemical Engineering Journal
dc.description.volume150
dc.description.issue1
dc.description.page213-222
dc.description.codenCMEJA
dc.identifier.isiut000266190200027