Please use this identifier to cite or link to this item: https://doi.org/10.1016/S1369-8001(02)00031-8
DC FieldValue
dc.titleDLTS characterisation of InGaAlP films grown using different V/III ratios
dc.contributor.authorLim, H.F.
dc.contributor.authorChi, D.Z.
dc.contributor.authorDong, J.R.
dc.contributor.authorSoh, C.B.
dc.contributor.authorChua, S.J.
dc.date.accessioned2014-10-07T04:43:33Z
dc.date.available2014-10-07T04:43:33Z
dc.date.issued2001-12
dc.identifier.citationLim, H.F., Chi, D.Z., Dong, J.R., Soh, C.B., Chua, S.J. (2001-12). DLTS characterisation of InGaAlP films grown using different V/III ratios. Materials Science in Semiconductor Processing 4 (6) : 625-629. ScholarBank@NUS Repository. https://doi.org/10.1016/S1369-8001(02)00031-8
dc.identifier.issn13698001
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/83644
dc.description.abstractDeep levels in InGaAlP films grown using two different V/III ratios have been studied by employing deep level transient spectroscopy (DLTS). The two samples investigated have the same composition of (Al0.3Ga0.7)0.51In0.49P and a film thickness of 0.6 μm, but grown with V/III ratios 75 and 50. Two defect levels with activation energies 0.23 and 0.78 eV are detected by temperature-scan DLTS in the sample with a V/III ratio of 75, with the 0.78 eV level being the dominant peak. Their respective capture cross-sections are 1.2 × 10-16 and 3.8 × 10-13 cm-2. The 0.78 eV trap level is also analysed using isothermal DLTS measurement and similar values of thermal signatures are obtained. The DLTS spectrum of the 0.78 eV trap level has been found to be broader than that expected for a point-type defect, implying that it may be associated with a complex or extended defect. The observation of logarithmic capture mechanism further supports this speculation. On the other hand, no peak corresponding to the 0.23 eV level appears in isothermal DLTS spectra, which is possibly due to the severe temperature dependence of capture rate and the system's limitation in the high-frequency regime. For the sample with a V/III ratio of 50, only one dominant electron trap level, with an activation energy of 0.42 eV and a capture cross-section of 1.4 × 10-17cm-2, is detected by isothermal DLTS method. © 2002 Elsevier Science Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S1369-8001(02)00031-8
dc.sourceScopus
dc.subjectDLTS
dc.subjectExtended defects
dc.subjectInGaAlP
dc.subjectLogarithmic capture
dc.typeConference Paper
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1016/S1369-8001(02)00031-8
dc.description.sourcetitleMaterials Science in Semiconductor Processing
dc.description.volume4
dc.description.issue6
dc.description.page625-629
dc.identifier.isiut000175066200031
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.