Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.bios.2008.09.002
Title: Modification of carbon nanotubes with redox hydrogel: Improvement of amperometric sensing sensitivity for redox enzymes
Authors: Cui, H.-F.
Ye, J.-S.
Zhang, W.-D.
Sheu, F.-S. 
Keywords: Amperometry
Carbon nanotubes
Electrochemical sensor
Enzyme activity
Redox enzymes
Redox polymer
Issue Date: 15-Feb-2009
Source: Cui, H.-F., Ye, J.-S., Zhang, W.-D., Sheu, F.-S. (2009-02-15). Modification of carbon nanotubes with redox hydrogel: Improvement of amperometric sensing sensitivity for redox enzymes. Biosensors and Bioelectronics 24 (6) : 1723-1729. ScholarBank@NUS Repository. https://doi.org/10.1016/j.bios.2008.09.002
Abstract: This study demonstrated that redox hydrogel-modified carbon nanotube (CNT) electrodes can be developed as an amperometric sensor that are sensitive, specific and fast and do not require auxiliary enzymes. A redox polymer, poly(vinylimidazole) complexed with Os(4,4′-dimethylbpy)2Cl (PVI-dmeOs) was electrodeposited on Ta-supported multi-walled CNTs. The resulted PVI-dmeOs thin film did not change the surface morphology of the CNTs, but turned the CNT surface from hydrophobic to hydrophilic, as studied by scanning electron microscopy (SEM) and static water contact angle measurements. Cyclic voltammetry measurements in a Fe(CN)6 3- solution and electrochemical impedance measurements in an equimolar Fe(CN)6 3-/4- solution demonstrated that the PVI-dmeOs hydrogel thin film was electronic conductive with a resistance of about 15 Ω. The PVI-dmeOs/CNT electrodes sensed rapidly, sensitively and specifically to model redox enzymes (glucose oxidase (GOD) and lactate oxidase (LOD)) in amperometric experiments in electrolyte solutions containing the substrates of the measured redox enzymes. Both the CNT substrate and the thin PVI-dmeOs film enhanced the sensing sensitivities. Exploration of the mechanisms suggests that the PVI-dmeOs film may enhance the sensing sensitivities by wiring the enzyme molecules through the redox centers tethered on the mobile redox polymer backbones to the CNT electrodes. Crown Copyright © 2008.
Source Title: Biosensors and Bioelectronics
URI: http://scholarbank.nus.edu.sg/handle/10635/82716
ISSN: 09565663
DOI: 10.1016/j.bios.2008.09.002
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

27
checked on Feb 22, 2018

WEB OF SCIENCETM
Citations

28
checked on Jan 29, 2018

Page view(s)

20
checked on Feb 19, 2018

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.