Please use this identifier to cite or link to this item: https://doi.org/10.1002/(SICI)1099-0801(199711)11:6<366
DC FieldValue
dc.titleSeparation of porphyrins by capillary electrophoresis in fused-silica and ethylene vinyl acetate copolymer capillaries with visible absorbance detection
dc.contributor.authorChiang, S.C.C.
dc.contributor.authorLi, S.F.Y.
dc.date.accessioned2014-06-23T05:49:12Z
dc.date.available2014-06-23T05:49:12Z
dc.date.issued1997-11
dc.identifier.citationChiang, S.C.C.,Li, S.F.Y. (1997-11). Separation of porphyrins by capillary electrophoresis in fused-silica and ethylene vinyl acetate copolymer capillaries with visible absorbance detection. Biomedical Chromatography 11 (6) : 366-370. ScholarBank@NUS Repository. <a href="https://doi.org/10.1002/(SICI)1099-0801(199711)11:6<366" target="_blank">https://doi.org/10.1002/(SICI)1099-0801(199711)11:6<366</a>
dc.identifier.issn02693879
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/76959
dc.description.abstractA mixture of 5 porphyrins were separated by capillary electrophoresis. A UV-VIS detector was used to detect the separated components. Separation was performed in 2 types of capillaries, i.e. fused-silica and ethylene vinyl acetate copolymer (EVA) plastic capillaries. The concentration limit of detection (CLOD), mass limit of detection (MLOD), and relative standard deviations (RSD) of migration time and area were investigated. LOD was comparable to that of epi-fluorescence detection. LOD was lower when separation was performed in EVA capillary compared to fused-silica capillary. RSD of migration times of the porphyrins when separated in fused-silica capillary ranges between 0.5 to 1.6% and in EVA capillary ranges between 0.3 to 1.2%. Area RSD in fused-silica capillary ranges between 7 to 20% and in EVA capillary ranges between 4.7 to 12.3%. Urine spiked with porphyrins was also analysed by CE using fused-silica and EVA capillaries. Analysis of urine sample spiked with porphyrins showed that stacking effect of porphyrins was observable only in fused-silica and not in EVA capillary. This led to similar LOD in fused-silica capillary to those for EVA capillary.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1002/(SICI)1099-0801(199711)11:6<366
dc.sourceScopus
dc.subjectCapillary electrophoresis
dc.subjectEthylene vinyl acetate copolymer capillaries
dc.subjectPorphyrins
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1002/(SICI)1099-0801(199711)11:6<366
dc.description.sourcetitleBiomedical Chromatography
dc.description.volume11
dc.description.issue6
dc.description.page366-370
dc.description.codenBICHE
dc.identifier.isiutA1997YG76100009
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric