DC Field | Value | |
---|---|---|
dc.title | Comparison of Supercritical Fluid Chromatographic and High-Performance Liquid Chromatographic Separations of p-tert-Butylcalix[n]arenes | |
dc.contributor.author | Graham, B.F. | |
dc.contributor.author | Harrowfield, J.M. | |
dc.contributor.author | Trengove, R.D. | |
dc.contributor.author | Rodriguez, I. | |
dc.contributor.author | Li, S.F.Y. | |
dc.date.accessioned | 2014-06-23T05:34:36Z | |
dc.date.available | 2014-06-23T05:34:36Z | |
dc.date.issued | 1997-05 | |
dc.identifier.citation | Graham, B.F.,Harrowfield, J.M.,Trengove, R.D.,Rodriguez, I.,Li, S.F.Y. (1997-05). Comparison of Supercritical Fluid Chromatographic and High-Performance Liquid Chromatographic Separations of p-tert-Butylcalix[n]arenes. Journal of Chromatographic Science 35 (5) : 232-236. ScholarBank@NUS Repository. | |
dc.identifier.issn | 00219665 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/75784 | |
dc.description.abstract | Supercritical fluid chromatography (SFC) using packed analytical columns is compared with high-performance liquid chromatography (HPLC) for the separation of the readily available calixarenes, p-tert-butylcalix[4]arene, p-tert-butylcalix[6]arene, and p-tert-butylcalix[8]arene. With methanol as a modifier in supercritical carbon dioxide, p-tert-butylcalix[8]arene fails to elute from any of the four different columns used (ODS, RP-18, Cyano, and Diol), although the smaller calixarenes elute; p-tert-butylcalix[4]arene always precedes p-tert-butylcalix[6]arene. By using chloroform modifier under gradient conditions, all three can be resolved, and a retention time as short as 1.4 min is obtained for p-tert-butylcalix[8]arene on an RP-18 column. The total run time including re-equilibration is slightly over 3 min. In contrast, the shortest retention time obtained for p-tert-butylcalix[8]arene by HPLC (150-mm ODS column, 3-μm particle size, isocratic conditions, acetonitrile-ethyl acetate mobile phase [80:20]) is approximately 5 min. Peaks are both narrower and more symmetrical under SFC rather than HPLC conditions. | |
dc.source | Scopus | |
dc.type | Article | |
dc.contributor.department | CHEMISTRY | |
dc.description.sourcetitle | Journal of Chromatographic Science | |
dc.description.volume | 35 | |
dc.description.issue | 5 | |
dc.description.page | 232-236 | |
dc.description.coden | JCHSB | |
dc.identifier.isiut | NOT_IN_WOS | |
Appears in Collections: | Staff Publications |