Please use this identifier to cite or link to this item: https://doi.org/10.1007/978-3-642-29305-4_379
Title: Particle Image Velocimetry (PIV) flow measurements of carotid artery bifurcation with application to a novel covered carotid stent design
Authors: Kabinejadian, F.
Leo, H.L. 
Danpinid, A.
Cui, F.
Zhang, Z.
Ho, P.
Keywords: carotid artery bifurcation
covered stent
emboli
Particle image velocimetry (PIV)
stroke
Issue Date: 2013
Source: Kabinejadian, F.,Leo, H.L.,Danpinid, A.,Cui, F.,Zhang, Z.,Ho, P. (2013). Particle Image Velocimetry (PIV) flow measurements of carotid artery bifurcation with application to a novel covered carotid stent design. IFMBE Proceedings 39 IFMBE : 1441-1444. ScholarBank@NUS Repository. https://doi.org/10.1007/978-3-642-29305-4_379
Abstract: Stenosed carotid artery is responsible for 60% of strokes in the United States and is the third major cause of death. Recently, there is an increasing interest in carotid artery stenting for treatment of cervical carotid artery bifurcation atherosclerotic disease. The ultimate goal of this study is to develop, prototype, test, and optimize a novel design of a covered carotid stent, in order to achieve emboli prevention and at the same time maintain the external carotid artery (ECA) branch flow. For this purpose, in the first stage, true-to-scale silicon replicas of anatomically realistic geometries of carotid arteries are fabricated and the flow field in the carotid bifurcation region is measured, utilizing particle image velocimetry (PIV) technique. These data are also used to validate the concurrent computational simulation results and fluid-structure interaction (FSI) analyses of the designed covered stents in the carotid artery models. Then, in the next stage, the stent prototypes will be deployed in the silicon models, and PIV flow measurements will be conducted to investigate the influence of each stent design on the flow behavior and the flow division between the internal and external carotid artery branches. Moreover, the capability of each covered stent design model in confining the atherosclerotic plaque fragments (emboli) will be evaluated experimentally. The preliminary stage of this study has demonstrated that the PIV and FSI computational simulations can complement each other to investigate the carotid flow towards our goal of determining the superior covered stent design that can bring about better emboli prevention and maintain the ECA branch vessel flow. © 2013 Springer-Verlag.
Source Title: IFMBE Proceedings
URI: http://scholarbank.nus.edu.sg/handle/10635/74911
ISBN: 9783642293047
ISSN: 16800737
DOI: 10.1007/978-3-642-29305-4_379
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

1
checked on Feb 20, 2018

Page view(s)

55
checked on Feb 22, 2018

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.