Please use this identifier to cite or link to this item:
https://doi.org/10.1109/ECTC.2007.374002
DC Field | Value | |
---|---|---|
dc.title | Design, fabrication and assembly of an optical biosensor probe package for OCT (Optical Coherence Tomography) application | |
dc.contributor.author | Premachandran, C.S. | |
dc.contributor.author | Sheng, K.C.W. | |
dc.contributor.author | Singh, J. | |
dc.contributor.author | Teo, J. | |
dc.contributor.author | Xu, Y. | |
dc.contributor.author | Chen, N. | |
dc.contributor.author | Sheppard, C. | |
dc.contributor.author | Olivo, M. | |
dc.date.accessioned | 2014-06-19T08:58:10Z | |
dc.date.available | 2014-06-19T08:58:10Z | |
dc.date.issued | 2007 | |
dc.identifier.citation | Premachandran, C.S., Sheng, K.C.W., Singh, J., Teo, J., Xu, Y., Chen, N., Sheppard, C., Olivo, M. (2007). Design, fabrication and assembly of an optical biosensor probe package for OCT (Optical Coherence Tomography) application. Proceedings - Electronic Components and Technology Conference : 1556-1560. ScholarBank@NUS Repository. https://doi.org/10.1109/ECTC.2007.374002 | |
dc.identifier.isbn | 1424409853 | |
dc.identifier.issn | 05695503 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/74846 | |
dc.description.abstract | A miniaturized optical bioprobe package is developed using a 3D micro mirror and is tested for bio-imaging application. A silicon optical bench is designed and micro machined to assemble the fiber, lens and the 3D micro mirror device. A 45 degree angle trench is used to place the micro mirror to achieve larger scanning range. Trace lines are formed on the optical bench and are connected to silicon micro mirror using solder. A GRIN lens with lower numerical aperture has been used to focus the optical beam onto the micro mirror. The bio probe is packaged and is tested in a Time domain OCT (Optical Coherence Tomography) setup and optical image is obtained for plant tissue. © 2007 IEEE. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/ECTC.2007.374002 | |
dc.source | Scopus | |
dc.type | Conference Paper | |
dc.contributor.department | BIOENGINEERING | |
dc.description.doi | 10.1109/ECTC.2007.374002 | |
dc.description.sourcetitle | Proceedings - Electronic Components and Technology Conference | |
dc.description.page | 1556-1560 | |
dc.description.coden | PECCA | |
dc.identifier.isiut | 000247705500235 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.