Please use this identifier to cite or link to this item: http://scholarbank.nus.edu.sg/handle/10635/74611
Title: Granular attrition due to rotary valve in a pneumatic conveying system
Authors: Yao, J.
Zhang, Y.
Wang, C.-H. 
Issue Date: 2004
Source: Yao, J.,Zhang, Y.,Wang, C.-H. (2004). Granular attrition due to rotary valve in a pneumatic conveying system. AIChE Annual Meeting, Conference Proceedings : 2749-2756. ScholarBank@NUS Repository.
Abstract: The rotary valve is a widely used mechanical device in many solids-handling industrial processes. However, it may also be responsible for most of the attrition effects occurring in a typical process. In this study, the attrition effects occurring in a rotary valve operating as a stand alone device and as part of a pneumatic conveying system are investigated. The Gwyn's correlation was found to fit the experimental data obtained in the former case and at high air flow rates in the latter.
Source Title: AIChE Annual Meeting, Conference Proceedings