Publication

Quantification of foaming behaviour using foam index

Ng, W.J.Ong, S.L.
Sarada, N.
Hu, J.Y.
Fan, X.J.
Ang, W.S.
Citations
Altmetric:
Alternative Title
Abstract
The factors influencing foam index were identified and their effects on foam index were investigated. It was noted that increasing the diameter of the flotation cell led to an increase in foam index. The maximum foam index was found to occur at a constant air/solids ratio when MLSS was varied with time of aeration or airflow. A good degree of correlation was also obtained between filament count and foam index. A small concentration of Surfactants was sufficient to induce foaming. However, further increase in surfactants showed relatively little influence on Foam Index.
Keywords
Absolute foam index, Air/solids, Airflow rate, Filament count, Foam index, True foam index