Please use this identifier to cite or link to this item: http://scholarbank.nus.edu.sg/handle/10635/71725
Title: Segmentation of cardiac MRI in a heart transplant study using rodent models
Authors: Jia, X. 
Li, C.
Sun, Y. 
Kassim, A.A. 
Wu, Y.L.
Hitchens, T.K.
Ho, C.
Keywords: Cardiac MRI segmentation
Left ventricle
Prior leaning
Temporal correlation
Issue Date: 2010
Source: Jia, X.,Li, C.,Sun, Y.,Kassim, A.A.,Wu, Y.L.,Hitchens, T.K.,Ho, C. (2010). Segmentation of cardiac MRI in a heart transplant study using rodent models. APSIPA ASC 2010 - Asia-Pacific Signal and Information Processing Association Annual Summit and Conference : 643-652. ScholarBank@NUS Repository.
Abstract: Cardiac MRI has been widely used in the study of heart diseases and transplant rejections using small animal models. But due to low image quality, quantitative analysis of the MRI data is generally performed through tedious manual segmentation. In this paper, a novel approach based on datadriven priors and temporal correlations is proposed for the segmentation of left ventricle myocardium in cardiac MR images of both native and transplanted rat hearts. To incorporate datadriven constraints into the segmentation, probabilistic maps generated based on prominent image features, i.e., corner points and scale-invariant edges, are used as priors for endocardium and epicardium segmentation, respectively. Non-rigid image registration is performed to obtain the deformation fields, which are then used to compute the averaged probabilistic priors and feature spaces. Integrating data-driven priors and temporal correlations with intensity, texture, and edge information, a level set formulation is adopted for segmentation. The proposed algorithm was applied to 3D+t cardiac MR images from eight rat studies. Experimental results show that with minimal user input, representative priors are correctly extracted from the data itself, and the proposed method is effective and robust for the segmentation of the left ventricle myocardium even in images with very low contrast. More importantly, it avoids interand intra- observer variations and makes accurate quantitative analysis of low-quality cardiac MR images possible.
Source Title: APSIPA ASC 2010 - Asia-Pacific Signal and Information Processing Association Annual Summit and Conference
URI: http://scholarbank.nus.edu.sg/handle/10635/71725
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Page view(s)

19
checked on Feb 16, 2018

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.