Source: Lim, H.F., Chua, S.J., Dong, J.R., Chi, D.Z., Soh, C.B. (2001). Effect of V/III ratio on extended defects in InGaAlP measured by isothermal DLTS. Proceedings of SPIE - The International Society for Optical Engineering 4598 : 125-132. ScholarBank@NUS Repository. https://doi.org/10.1117/12.447100
Abstract: Deep level transient spectroscopy (DLTS) characterization of defects in InGaAlP films grown using two different V/III ratios was carried out. Electron trap levels with activation energies of 0.42 eV and 0.78 eV were detected in the sample with V/III ratio of 50 and 75 respectively, using isothermal DLTS. In this paper, the severe temperature dependence of the DLTS signals observed for these two trap levels is explained in terms of the presence of noticeable capture barriers for electrons. The capture barrier heights of 0.27 and 0.13 eV were estimated for trap levels of 0.42 eV and 0.78 eV respectively. It is believed that these two trap levels are associated with extended defects based on the observation of logarithmic dependence of the DLTS signal on filling pulse width. This is further supported by the observation of a broader temperature scan spectrum in the sample with V/III ratio of 75. For the sample with a V/III ratio of 50, a monotonic increase in DLTS signal with temperature was observed for temperature scan DLTS up to the upper limit of the system. Although the two defect levels observed in this study appear both to be related to extended defects, they are related to two different defects simply due to the observation of much different thermal signatures for these two defects. The results indicate that a V/III ratio of 50 is a better choice as the associated defect has a smaller capture cross-section and a larger capture barrier.
Source Title: Proceedings of SPIE - The International Society for Optical Engineering
URI: http://scholarbank.nus.edu.sg/handle/10635/70091
ISSN: 0277786X
DOI: 10.1117/12.447100
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Page view(s)

26
checked on Dec 10, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.