Please use this identifier to cite or link to this item:
https://doi.org/10.1109/BioCAS.2012.6418512
DC Field | Value | |
---|---|---|
dc.title | A smart cushion for real-time heart rate monitoring | |
dc.contributor.author | Deepu, C.J. | |
dc.contributor.author | Chen, Z. | |
dc.contributor.author | Teo, J.T. | |
dc.contributor.author | Ng, S.H. | |
dc.contributor.author | Yang, X. | |
dc.contributor.author | Lian, Y. | |
dc.date.accessioned | 2014-06-19T02:56:35Z | |
dc.date.available | 2014-06-19T02:56:35Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Deepu, C.J., Chen, Z., Teo, J.T., Ng, S.H., Yang, X., Lian, Y. (2012). A smart cushion for real-time heart rate monitoring. 2012 IEEE Biomedical Circuits and Systems Conference: Intelligent Biomedical Electronics and Systems for Better Life and Better Environment, BioCAS 2012 - Conference Publications : 53-56. ScholarBank@NUS Repository. https://doi.org/10.1109/BioCAS.2012.6418512 | |
dc.identifier.isbn | 9781467322935 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/69078 | |
dc.description.abstract | This paper presents a smart cushion for real time heart rate monitoring. The cushion comprises of an integrated micro-bending fiber sensor, which records the BCG (Ballistocardiogram) signal without direct skin-electrode contact, and an optical transceiver that does signal amplification, digitization, and pre-filtering. To remove the artifacts and extract heart rate from BCG signal, a computationally efficient heart rate detection algorithm is developed. The system doesn't require any pre-training and is highly responsive with the outputs updated every 3 sec and initial response within first 10 sec. Tests conducted on human subjects show the detected heart rate closely matches the one from a commercial SpO2 device. © 2012 IEEE. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/BioCAS.2012.6418512 | |
dc.source | Scopus | |
dc.subject | Ballistocardiogram | |
dc.subject | Contactless heart rate detection | |
dc.subject | MRI friendly heart rate monitoring | |
dc.subject | Smart Cushion | |
dc.type | Conference Paper | |
dc.contributor.department | ELECTRICAL & COMPUTER ENGINEERING | |
dc.description.doi | 10.1109/BioCAS.2012.6418512 | |
dc.description.sourcetitle | 2012 IEEE Biomedical Circuits and Systems Conference: Intelligent Biomedical Electronics and Systems for Better Life and Better Environment, BioCAS 2012 - Conference Publications | |
dc.description.page | 53-56 | |
dc.identifier.isiut | NOT_IN_WOS | |
Appears in Collections: | Staff Publications Elements |
Show simple item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
2012-a_smart_cushion_for_real-time_heart-postprint.pdf | 649.18 kB | Adobe PDF | OPEN | Post-print | View/Download |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.