Title: Effectiveness of tuned liquid column dampers for vibration control of towers
Authors: Balendra, T. 
Wang, C.M. 
Cheong, H.F. 
Keywords: towers
tuned liquid column dampers
wind-induced vibration
Issue Date: Nov-1995
Source: Balendra, T.,Wang, C.M.,Cheong, H.F. (1995-11). Effectiveness of tuned liquid column dampers for vibration control of towers. Engineering Structures 17 (9) : 668-675. ScholarBank@NUS Repository.
Abstract: The effectiveness of tuned liquid column dampers (TLCD) in controlling the wind-induced vibration of towers is studied. The nonlinear governing equation of the TLCD is linearized to obtain the stochastic response of the towers due to along-wind turbulence. Through parametric studies, the optimum parameters for maximum reduction in acceleration and displacement are presented for a wide range of towers. It is found that for any tower of practical interest, almost the same amount of reduction in acceleration can be obtained by choosing an appropriate opening ratio of the orifice in the TLCD. The same opening ratio would give almost the maximum reduction in displacement. Generally, the opening ratio needs to be varied between 0.5 and 1.0, with smaller opening ratios for shorter towers. © 1995.
Source Title: Engineering Structures
URI: http://scholarbank.nus.edu.sg/handle/10635/65500
ISSN: 01410296
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Page view(s)

31
checked on Dec 15, 2017

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.