Please use this identifier to cite or link to this item: https://doi.org/10.1088/0022-3727/38/18/029
DC FieldValue
dc.titleTribology of PFPE overcoated self-assembled monolayers deposited on Si surface
dc.contributor.authorSatyanarayana, N.
dc.contributor.authorSinha, S.K.
dc.date.accessioned2014-06-17T06:37:25Z
dc.date.available2014-06-17T06:37:25Z
dc.date.issued2005-09-21
dc.identifier.citationSatyanarayana, N., Sinha, S.K. (2005-09-21). Tribology of PFPE overcoated self-assembled monolayers deposited on Si surface. Journal of Physics D: Applied Physics 38 (18) : 3512-3522. ScholarBank@NUS Repository. https://doi.org/10.1088/0022-3727/38/18/029
dc.identifier.issn00223727
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/61626
dc.description.abstractFriction and wear characteristics of monomolecular layers of self-assembled monolayers (SAMs) with and without perfluoropolyether (PFPE) overcoat were studied using ball-on-disk experiments. Ultra-thin layer of PFPE was dip-coated onto two different SAMs, one with non-reactive terminal group (octadecyltrichlorosilane (OTS)) and the other with reactive terminal group (3-aminopropyltrimethoxysilane (APTMS)), which were formed on Si substrate by self-assembly. The effects of PFPE overcoating on physical and chemical properties were evaluated using contact angle measurement and x-ray photoelectron spectroscopy. For a comparison, PFPE was also coated onto the Si surface and their properties were evaluated. All PFPE modified surfaces were baked at 150°C for 2 h, to investigate the effect of thermal treatment on tribological properties. PFPE coating has shown higher water contact angles irrespective of the SAM surface. Coating of PFPE on both SAM surfaces has lowered their coefficients of friction. PFPE overcoating has shown remarkable increase in the wear resistance when it was coated on reactive APTMS SAM and little increase on OTS SAM. Thermal treatment after PFPE coating onto SAMs further reduced the coefficient of friction to a smaller extent. Moreover, thermal treatment has shown an additional increase in wear-life by approximately 30% in the case of PFPE coated APTMS SAM surface and a decrease in the wear-life in the case of PFPE coated OTS SAM. The reasons for these observed phenomena are explained in terms of the amounts of PFPE bonded or mobile, surface energies of SAMs, uniformity and molecular packing of SAM surfaces. © 2005 IOP Publishing Ltd.
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1088/0022-3727/38/18/029
dc.description.sourcetitleJournal of Physics D: Applied Physics
dc.description.volume38
dc.description.issue18
dc.description.page3512-3522
dc.description.codenJPAPB
dc.identifier.isiut000232452900030
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.