Title: Non-destructive characterization of resin-based filling materials using Electronic Speckle Pattern Interferometry
Authors: Yap, A.U.J. 
Tan, A.C.S.
Quan, C. 
Keywords: Composite resin
Dental material
Electronic speckle pattern interferometry
Flexural
Interferometry
Modulus
Issue Date: May-2004
Source: Yap, A.U.J., Tan, A.C.S., Quan, C. (2004-05). Non-destructive characterization of resin-based filling materials using Electronic Speckle Pattern Interferometry. Dental Materials 20 (4) : 377-382. ScholarBank@NUS Repository. https://doi.org/10.1016/j.dental.2003.06.002
Abstract: Objectives. The aim of this study was to develop a non-destructive test for characterizing the modulus of resin-based filling materials. Methods. Five different visible-light-cured composites (Filtek A110 [AO], Z100 [ZO], Filtek Z250 [ZT], F2000 [FT] and Filtek Flow [FF]; 3M-ESPE) were selected for this study. An ESPI (Electronic Speckle Pattern Interferometry) apparatus involving cantilever beam specimens (28 mm long, 8 mm wide and 2 mm thick) was developed for determining modulus. Out-of-plane displacement upon force application was measured using two focus region lengths (22 mm [EI1]; 11 mm [EI2]) and modulus (n=7) was subsequently computed based on cantilever beam equations. Data was compared to those obtained from three-point-bend flexural testing (n=7) based on ISO4049:2000 specifications [ISO]. Specimens were stored in distilled water at 37 °C for 1 week prior to evaluation for all tests. Results were analyzed using ANOVA/Scheffe's post-hoc tests (p<0.05) and Pearson's correlation (p<0.01). Results. Modulus ranged from 5.53 to 13.99, 5.78 to 14.24 and 4.26 to 11.30 GPa for EI1, EI2 and ISO, respectively. For all three tests, the modulus of ZO and FT was significantly greater than ZT, which in turn was significantly greater than AO and FF. Correlation of EI1 and EI2 to ISO was significant, positive and very strong (r=0.94 for EI1 and EI2). Significance. ESPI may be a viable method of characterizing the modulus of resin-based filling materials. As it is a non-destructive test, time-dependent effects of composites can be determined using the same specimens leading to substantial time and material savings. © 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Source Title: Dental Materials
URI: http://scholarbank.nus.edu.sg/handle/10635/60886
ISSN: 01095641
DOI: 10.1016/j.dental.2003.06.002
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

5
checked on Dec 13, 2017

WEB OF SCIENCETM
Citations

4
checked on Nov 16, 2017

Page view(s)

42
checked on Dec 16, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.