Please use this identifier to cite or link to this item: https://doi.org/10.1142/S1758825110000718
Title: Effects of balloon length and compliance on vascular stent expansion
Authors: Cui, F.S.
Lee, H.P. 
Lu, C.
Chai, P.
Keywords: finite element method
longitudinal geographic miss
stent design
Vascular stent
Issue Date: Sep-2010
Source: Cui, F.S., Lee, H.P., Lu, C., Chai, P. (2010-09). Effects of balloon length and compliance on vascular stent expansion. International Journal of Applied Mechanics 2 (3) : 681-697. ScholarBank@NUS Repository. https://doi.org/10.1142/S1758825110000718
Abstract: Vascular stents are used to dilate arteries that are narrowed or clogged by plaque. However, in-stent restenosis is still one of the major causes of the clinical failure. It is believed that vessel trauma imposed during stent deployment is closely correlated to restenosis. Clinical observations show that the longitudinal and axial geographic miss in pre/post-dilation are responsible for the vessel trauma. The interactions between the stent-strut and the artery are difficult to measure in vivo or clinically and reported results are very limited. A numerical approach that leverages on computing power can provide new insights into the stent implantation process. In this study, the effects of balloon length and compliance that play important roles during stent expansion were investigated. Areas in the vessels with high stress concentrations were identified as these were weaknesses that might have a high possibility of vascular injury. Two different types of numerical models were constructed: a simplified model that considered only the balloon and stent and a more comprehensive model that consisted of the balloon, stent, plaque, and artery. Virtual stent implantation trials were simulated and the phenomena of stent recoil, dogboning and foreshortening were observed and examined. It was found that balloons which were slightly longer than the stent and less compliance would be more likely to eliminate dogboning. Furthermore, a new parameter, namely the Ectropion angle, was introduced to describe the turning effect of the stent end in situations when dogboning could not adequately characterize this phenomenon. The present study could provide guidance for the placement of stents by clinical practitioners. © 2010 Imperial College Press.
Source Title: International Journal of Applied Mechanics
URI: http://scholarbank.nus.edu.sg/handle/10635/60094
ISSN: 17588251
DOI: 10.1142/S1758825110000718
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

6
checked on Dec 6, 2017

WEB OF SCIENCETM
Citations

5
checked on Nov 22, 2017

Page view(s)

57
checked on Dec 10, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.