Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.jbiomech.2008.03.042
DC FieldValue
dc.titleApplication of motion analysis system in pre-impact fall detection
dc.contributor.authorNyan, M.N.
dc.contributor.authorTay, F.E.H.
dc.contributor.authorMah, M.Z.E.
dc.date.accessioned2014-06-17T06:12:56Z
dc.date.available2014-06-17T06:12:56Z
dc.date.issued2008-07-19
dc.identifier.citationNyan, M.N., Tay, F.E.H., Mah, M.Z.E. (2008-07-19). Application of motion analysis system in pre-impact fall detection. Journal of Biomechanics 41 (10) : 2297-2304. ScholarBank@NUS Repository. https://doi.org/10.1016/j.jbiomech.2008.03.042
dc.identifier.issn00219290
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/59564
dc.description.abstractThe purpose of this study is to investigate unique features of body segments in fall and activities of daily living (ADL) to make automatic detection of fall in its descending phase before the impact. Thus, fall-related injuries can be prevented or reduced by deploying feedback systems before the impact. In this study, the authors propose the following hypothesis: (1) thigh segment normally does not go beyond certain threshold angle to forward and sideways directions in ADL and (2) even if it does, the angular characteristics measured at torso and thigh differ from one another in ADL whereas in the case of fall, they become congruent. These two factors can be used to distinguish fall from ADL in its inception. Vicon 3-D motion analysis system was used in this study. High level of correlation between thigh and torso segments (corr > 0.99) was found for fall activities and low correlation coefficients (mean corr for lateral movements is 0.2338 and for sagittal movements is -0.665) were observed in ADL. By applying the hypothesis, all simulated falls could be detected with no false alarms and around 700 ms lead-time before the impact was achieved in pre-impact fall detection. It is the longest lead-time obtained so far in pre-impact fall detection.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.jbiomech.2008.03.042
dc.sourceScopus
dc.subjectElderly
dc.subjectFaint fall
dc.subjectMotion analysis system
dc.subjectSyncope
dc.subjectVicon
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.jbiomech.2008.03.042
dc.description.sourcetitleJournal of Biomechanics
dc.description.volume41
dc.description.issue10
dc.description.page2297-2304
dc.description.codenJBMCB
dc.identifier.isiut000258354200028
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.