Title: Intensity-modulated microbend fiber optic sensor for respiratory monitoring and gating during MRI
Authors: Lau, D.
Chen, Z.
Teo, J.T.
Ng, S.H.
Rumpel, H.
Lian, Y. 
Yang, H.
Kei, P.L.
Keywords: Fiber optic sensor (FOS)
magnetic resonance imaging (MRI)
microbending
respiratory gating
respiratory monitoring
Issue Date: 2013
Citation: Lau, D., Chen, Z., Teo, J.T., Ng, S.H., Rumpel, H., Lian, Y., Yang, H., Kei, P.L. (2013). Intensity-modulated microbend fiber optic sensor for respiratory monitoring and gating during MRI. IEEE Transactions on Biomedical Engineering 60 (9) : 2655-2662. ScholarBank@NUS Repository. https://doi.org/10.1109/TBME.2013.2262150
Abstract: This paper describes a novel microbend fiber optic sensor system for respiratory monitoring and respiratory gating in the MRI environment. The system enables the noninvasive real-time monitoring and measurement of breathing rate and respiratory/body movement pattern of healthy subjects inside the MRI gantry, and has potential application in respiratory-gated image acquisition based on respiratory cues. The working principle behind this sensor is based on the microbending effect of an optical fiber on light transmission. The sensor system comprises of a 1.0-mm-thin graded-index multimode optical fiber-embedded plastic sensor mat, a photoelectronic transceiver, and a computer with a digital signal processing algorithm. In vitro testing showed that our sensor has a typical signal-to-noise ratio better than 28 dB. Clinical MRI trials conducted on 20 healthy human subjects showed good and comparable breathing rate detection (with an accuracy of ±2 bpm) and respiratory-gated image quality produced using the sensor system, with reference to current predicate hospital device/system. The MRI safe, ease of operation characteristics, low fabrication cost, and extra patient comfort offered by this system suggest its good potential in replacing predicate device/system and serve as a dual function in real-time respiratory monitoring and respiratory-gated image acquisition at the same time during MRI. © 1964-2012 IEEE.
Source Title: IEEE Transactions on Biomedical Engineering
URI: http://scholarbank.nus.edu.sg/handle/10635/56360
ISSN: 00189294
DOI: 10.1109/TBME.2013.2262150
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

25
checked on Sep 11, 2018

WEB OF SCIENCETM
Citations

23
checked on Sep 11, 2018

Page view(s)

32
checked on Aug 17, 2018

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.