Title: Design of a plug-in repetitive control scheme for eliminating supply-side current harmonics of three-phase pwm boost rectifiers under generalized supply voltage conditions
Authors: Wu, X.H.
Panda, S.K. 
Xu, J.X. 
Keywords: AC-DC power conversion
pulsewidth-modulated (PWM) power converters
rectifiers
repetitive control (RC)
Issue Date: 2010
Source: Wu, X.H., Panda, S.K., Xu, J.X. (2010). Design of a plug-in repetitive control scheme for eliminating supply-side current harmonics of three-phase pwm boost rectifiers under generalized supply voltage conditions. IEEE Transactions on Power Electronics 25 (7) : 1800-1810. ScholarBank@NUS Repository. https://doi.org/10.1109/TPEL.2010.2042304
Abstract: This paper presents a digital repetitive control (RC) scheme to minimize the even-order harmonics at the dc link voltage and odd-order harmonics in the line-side currents under distorted and unbalanced supply voltage conditions. The proposed current control scheme consists of a conventional PI and a plug-in repetitive controller. On the basis of the mathematical model of the three-phase pulsewidth-modulated (PWM) boost rectifier under the generalized supply voltage conditions, the control task is divided into: 1) dc-link voltage harmonics control and 2) line-side current harmonics control. In the voltage harmonics control scheme, a reference current calculation algorithm has been derived accordingly to ensure that the dc link voltage is maintained constant at the demanded value and the supply-side power factor is kept close to unity. In the line-side current harmonics control scheme, a plug-in repetitive controller is designed to achieve low total harmonic distortion (THD) line-side currents of the three-phase PWM boost rectifier. The experimental test results obtained from a 1.6-kVA laboratory-based PWM rectifier confirm that the proposed control scheme can reduce the line-side current THD from 16.63 to 4.70, and improve the dc-link voltage tracking accuracy substantially over the conventional PI-based controller. © 2011 IEEE.
Source Title: IEEE Transactions on Power Electronics
URI: http://scholarbank.nus.edu.sg/handle/10635/55569
ISSN: 08858993
DOI: 10.1109/TPEL.2010.2042304
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

78
checked on Dec 6, 2017

WEB OF SCIENCETM
Citations

56
checked on Nov 21, 2017

Page view(s)

26
checked on Dec 10, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.