Please use this identifier to cite or link to this item:
https://doi.org/10.1109/TPEL.2010.2042304
Title: | Design of a plug-in repetitive control scheme for eliminating supply-side current harmonics of three-phase pwm boost rectifiers under generalized supply voltage conditions | Authors: | Wu, X.H. Panda, S.K. Xu, J.X. |
Keywords: | AC-DC power conversion pulsewidth-modulated (PWM) power converters rectifiers repetitive control (RC) |
Issue Date: | 2010 | Citation: | Wu, X.H., Panda, S.K., Xu, J.X. (2010). Design of a plug-in repetitive control scheme for eliminating supply-side current harmonics of three-phase pwm boost rectifiers under generalized supply voltage conditions. IEEE Transactions on Power Electronics 25 (7) : 1800-1810. ScholarBank@NUS Repository. https://doi.org/10.1109/TPEL.2010.2042304 | Abstract: | This paper presents a digital repetitive control (RC) scheme to minimize the even-order harmonics at the dc link voltage and odd-order harmonics in the line-side currents under distorted and unbalanced supply voltage conditions. The proposed current control scheme consists of a conventional PI and a plug-in repetitive controller. On the basis of the mathematical model of the three-phase pulsewidth-modulated (PWM) boost rectifier under the generalized supply voltage conditions, the control task is divided into: 1) dc-link voltage harmonics control and 2) line-side current harmonics control. In the voltage harmonics control scheme, a reference current calculation algorithm has been derived accordingly to ensure that the dc link voltage is maintained constant at the demanded value and the supply-side power factor is kept close to unity. In the line-side current harmonics control scheme, a plug-in repetitive controller is designed to achieve low total harmonic distortion (THD) line-side currents of the three-phase PWM boost rectifier. The experimental test results obtained from a 1.6-kVA laboratory-based PWM rectifier confirm that the proposed control scheme can reduce the line-side current THD from 16.63 to 4.70, and improve the dc-link voltage tracking accuracy substantially over the conventional PI-based controller. © 2011 IEEE. | Source Title: | IEEE Transactions on Power Electronics | URI: | http://scholarbank.nus.edu.sg/handle/10635/55569 | ISSN: | 08858993 | DOI: | 10.1109/TPEL.2010.2042304 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.