Please use this identifier to cite or link to this item: https://doi.org/10.1088/0967-3334/31/9/N01
DC FieldValue
dc.titleA comparative study of histogram-based thresholding methods for the determination of cell-free layer width in small blood vessels
dc.contributor.authorNamgung, B.
dc.contributor.authorOng, P.K.
dc.contributor.authorWong, Y.H.
dc.contributor.authorLim, D.
dc.contributor.authorChun, K.J.
dc.contributor.authorKim, S.
dc.date.accessioned2014-06-16T09:24:41Z
dc.date.available2014-06-16T09:24:41Z
dc.date.issued2010-09
dc.identifier.citationNamgung, B., Ong, P.K., Wong, Y.H., Lim, D., Chun, K.J., Kim, S. (2010-09). A comparative study of histogram-based thresholding methods for the determination of cell-free layer width in small blood vessels. Physiological Measurement 31 (9) : N61-N70. ScholarBank@NUS Repository. https://doi.org/10.1088/0967-3334/31/9/N01
dc.identifier.issn09673334
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/53973
dc.description.abstractWe have recently proposed a computer-based method utilizing a thresholding algorithm (the Otsu method) to provide a convenient way of measuring the cell-free layer width in vivo and in vitro. However, this method does not seem to be a universal method that can be applied to all microvascular studies. Thus, we examined four different histogram-based thresholding algorithms (Otsu, intermode, minimum and second peak) to provide a technical suggestion on the selection of a suitable thresholding algorithm for the cell-free layer measurement. All the measurements were taken in microvascular flows in the rat cremaster muscle recorded with a high-speed camera. The width of the cell-free layer manually measured was compared with that determined by the automated method utilizing the four thresholding algorithms. With our experimental system, results showed that the cell-free layer width determined by the minimum algorithm was in best accordance with the manual measurement. We concluded that the accuracy of the automated methods for determination of the cell-free layer width would depend on the image quality, in particular on the contrast between the red blood cell core and background, which might differ due to the different microscopic setup. Therefore, one may need to examine several appropriate thresholding methods when selecting the best suitable algorithm for the experimental conditions. © 2010 Institute of Physics and Engineering in Medicine.
dc.sourceScopus
dc.subjectCell-free layer
dc.subjectHemodynamics
dc.subjectThresholding method
dc.typeArticle
dc.contributor.departmentBIOENGINEERING
dc.description.doi10.1088/0967-3334/31/9/N01
dc.description.sourcetitlePhysiological Measurement
dc.description.volume31
dc.description.issue9
dc.description.pageN61-N70
dc.description.codenPMEAE
dc.identifier.isiut000280801900016
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.