Please use this identifier to cite or link to this item: http://scholarbank.nus.edu.sg/handle/10635/52692
Title: Determination of equilibrium isotherms using dynamic column breakthrough and constant flow equilibrium desorption
Authors: Malek, A. 
Farooq, S. 
Issue Date: Jan-1996
Source: Malek, A.,Farooq, S. (1996-01). Determination of equilibrium isotherms using dynamic column breakthrough and constant flow equilibrium desorption. Journal of Chemical and Engineering Data 41 (1) : 25-32. ScholarBank@NUS Repository.
Abstract: Reliable adsorption equilibrium data are key elements in the design of an adsorption separation process. Two excellent metnods for obtaining single-componet equilbrium isotherm data are the dynamic column breakthrough method and the constant flow equilibrium desoprion method. Both these methods were used to derive the equilibrium isotherms of methane, ethane, and propane in activated carbon and silica gel. The experimental setup and analysis required for these methods are elaborated. The equilibrium results for these gases for a moderate pressure range and at three different temperatures are presented.
Source Title: Journal of Chemical and Engineering Data
URI: http://scholarbank.nus.edu.sg/handle/10635/52692
ISSN: 00219568
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Page view(s)

35
checked on Feb 23, 2018

Google ScholarTM

Check