Please use this identifier to cite or link to this item: https://doi.org/10.1177/0218492311411315
DC FieldValue
dc.titleNanofiber-reinforced biological conduit in cardiac surgery: Preliminary report
dc.contributor.authorGuhathakurta, S.
dc.contributor.authorGalla, S.
dc.contributor.authorRamesh, B.
dc.contributor.authorVenugopal, J.R.
dc.contributor.authorRamakrishna, S.
dc.contributor.authorCherian, K.M.
dc.date.accessioned2014-04-24T09:35:33Z
dc.date.available2014-04-24T09:35:33Z
dc.date.issued2011
dc.identifier.citationGuhathakurta, S.,Galla, S.,Ramesh, B.,Venugopal, J.R.,Ramakrishna, S.,Cherian, K.M. (2011). Nanofiber-reinforced biological conduit in cardiac surgery: Preliminary report. Asian Cardiovascular and Thoracic Annals 19 (3-4) : 207-212. ScholarBank@NUS Repository. <a href="https://doi.org/10.1177/0218492311411315" target="_blank">https://doi.org/10.1177/0218492311411315</a>
dc.identifier.issn02184923
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/51473
dc.description.abstractSeveral options are available for right ventricular outflow tract reconstruction, including commercially available bovine jugular vein and cryo-preserved homografts. Homograft non-availability and the problems of commercially available conduits led us to develop indigenously processed bovine jugular vein conduits with competent valves. They were made completely acellular and strengthened by non-conventional cross-linking without disturbing the extracellular matrix, which improved the luminal surface characteristics for hemocompatibility. Biocompatibility in vitro and in vivo, along with thermal stability, matrix stability, and mechanical strength have been evaluated. Sixty-nine patients received these conduits for right ventricular outflow tract reconstruction. Seven conduits dilated and 4 required replacement. To counteract dilatation, biodegradable polymeric nanofibers in various combinations and in isolation (collagen, polycaprolactone, polylactic acid) were characterized and used to reinforce the conduit circumferentially. Physical validation by mechanical testing, scanning electron microscopy, and in-vitro cytotoxicity was conducted. Thermal stability, spectroscopy studies of the polymer, and preclinical studies of the coated bovine jugular vein in animals are in progress. The feasibility studies have been completed, and the final polymer selection depends on evaluation of the functional superiority of the coated bovine jugular vein. © 2011 The Author(s).
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1177/0218492311411315
dc.sourceScopus
dc.subjectBlood vessel prosthesis
dc.subjectElectrochemical techniques
dc.subjectMechanical phenomena
dc.subjectNanofibers
dc.subjectTissue engineering
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.contributor.departmentNUS NANOSCIENCE & NANOTECH INITIATIVE
dc.description.doi10.1177/0218492311411315
dc.description.sourcetitleAsian Cardiovascular and Thoracic Annals
dc.description.volume19
dc.description.issue3-4
dc.description.page207-212
dc.description.codenACTAF
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.