Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.clinbiomech.2005.02.005
Title: Development of an integrated CAD-FEA process for below-knee prosthetic sockets
Authors: Goh, J.C.H. 
Lee, P.V.S. 
Toh, S.L. 
Ooi, C.K. 
Keywords: Computer-aided design
Finite element analysis
Interface pressure
Lower limb prosthesis
Pressure distribution
Rehabilitation
Socket fit
Validation procedure
Issue Date: Jul-2005
Source: Goh, J.C.H., Lee, P.V.S., Toh, S.L., Ooi, C.K. (2005-07). Development of an integrated CAD-FEA process for below-knee prosthetic sockets. Clinical Biomechanics 20 (6) : 623-629. ScholarBank@NUS Repository. https://doi.org/10.1016/j.clinbiomech.2005.02.005
Abstract: Background. Computer-aided design and manufacturing has been successfully used in prosthetic applications since 1980s. It simplifies the socket rectification process and improves reproducibility but does not introduce any new principle into socket design. Integrating finite element analysis to CAD will provide a more objective assessment of socket fit and improve the chance of a successful first fitting. Methods. Current study aims to establish a finite element model generation technique directly from geometrical information of commercial prosthetic CAD workstation. A program developed in-house automatically performs meshing of the stump geometry and assigns suitable material properties, load and boundary conditions to the model. The model was validated by comparing predicted pressure with experimentally measured values for one amputee subject. Findings. The predicted pressure distribution has an root-mean-square error of 8.8 kPa compared to experimental values at 10%, 25% and 50% of the gait cycle. Interpretation. Current method was able to develop a finite element model to predict interface pressure reasonably well and can be integrated with prosthetic CAD system to provide quantitative feedback to the prosthetist in an automated process. © 2005 Elsevier Ltd. All rights reserved.
Source Title: Clinical Biomechanics
URI: http://scholarbank.nus.edu.sg/handle/10635/51375
ISSN: 02680033
DOI: 10.1016/j.clinbiomech.2005.02.005
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

27
checked on Dec 13, 2017

WEB OF SCIENCETM
Citations

20
checked on Nov 14, 2017

Page view(s)

53
checked on Dec 9, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.