Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/46763
Title: Surface laser scanning of the cleft palate deformity - Validation of the method
Authors: Foong, K.W.C. 
Sandham, A.
Ong, S.H.
Wong, C.W.
Wang, Y.
Kassim, A.
Keywords: Cartesian coordinate
Landmark localisation
Reliability
Surface characterisation
Three-dimensional measurement
Issue Date: 1999
Citation: Foong, K.W.C.,Sandham, A.,Ong, S.H.,Wong, C.W.,Wang, Y.,Kassim, A. (1999). Surface laser scanning of the cleft palate deformity - Validation of the method. Annals of the Academy of Medicine Singapore 28 (5) : 642-649. ScholarBank@NUS Repository.
Abstract: Innovations in laser technology have led to the development of three-dimensional surface laser digitisation techniques capable of registering surface topology accurately. The clinical application of this technology in cleft palate documentation requires validation of the technique. This study determined the reliability of the surface laser scanning technique and assessed the reliability of interactive threedimensional landmark localisation. Original and duplicate plaster models of an infant with a complete unilateral cleft lip and palate were digitised with the Cyberware 3030R-HIREZ surface laser scanner. Seven anatomic landmarks were marked permanently on the palatal surface of the duplicate model only, which acted as visual cues for landmark localisation. Each model was scanned ten times serially, and ten composite three-dimensional images were obtained for each. On-line interactive computer landmark localisation permitted the assessment of variance for the x, y and z coordinates of each landmark. The precision of the laser scanning technique was found to be less than 0.06 mm in all three axes. Anatomic landmarks with the clearest visual cue were the least variable after ten rounds of scanning. Significant differences existed between visually aided and non-aided landmark localisation (P <0.05). While landmarks could be localised repeatedly without the aid of a visual marker, landmarks well defined by a clearly visible visual cue on the three-dimensional image were more reliable.
Source Title: Annals of the Academy of Medicine Singapore
URI: http://scholarbank.nus.edu.sg/handle/10635/46763
ISSN: 03044602
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.