Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.atmosenv.2007.11.041
DC FieldValue
dc.titleIndoor air quality and its determinants in tropical child care centers
dc.contributor.authorZuraimi, M.S.
dc.contributor.authorTham, K.W.
dc.date.accessioned2013-10-14T04:38:52Z
dc.date.available2013-10-14T04:38:52Z
dc.date.issued2008
dc.identifier.citationZuraimi, M.S., Tham, K.W. (2008). Indoor air quality and its determinants in tropical child care centers. Atmospheric Environment 42 (9) : 2225-2239. ScholarBank@NUS Repository. https://doi.org/10.1016/j.atmosenv.2007.11.041
dc.identifier.issn13522310
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/45728
dc.description.abstractThis cross-sectional study aims to investigate indoor pollutants concentrations in child care centers (CCCs) and evaluate their determinants involving representative samples in Singapore. Measurements were performed for air temperature, relative humidity, air velocity, ventilation rates, carbon dioxide, carbon monoxide, ozone, fine particle mass, bacteria and fungi while information on CCC characteristics and maintenance activities were collected via a combination of inspection and interviews. It was found that due to higher ventilation rates, indoor CO2 concentration levels were lower in Singapore CCCs compared to those in the cold climates. Determinants of indoor pollutant levels from outdoor and indoor sources and maintenance activities were evaluated with regression analyses based on mass balance principles. Indoor carbon dioxide was positively associated with outdoor concentrations and occupant density while only outdoor levels significantly determined indoor carbon monoxide concentrations. For PM2.5, outdoor concentration, carpeted floor, presence of curtains and soft toys, recent renovation, shelf area and fan cleaning frequencies were positively associated with indoor levels while determinants of indoor ozone include outdoor concentration, shelf area and table cleaning. Increased human related bacteria levels were associated with high occupant densities and irregular floor but regular table cleaning frequencies. Outdoor concentration, curtain types and floor cleaning were significant determinants for environmental bacteria. Outdoor concentrations, presence of dampness, irregular floor and fan cleaning were associated with increased indoor mesophilic fungi levels. For indoor xerophilic fungi, levels were associated with outdoor concentrations, curtain types, dampness, occupant density and floor cleaning. We conclude that our findings confirm the important influence of indoor sources and maintenance activities on indoor concentrations of pollutants in Singapore CCCs. Future epidemiological analyses in CCCs should consider these determinants in classifying exposures as surrogate indicators of sources and cleaning activities. © 2007 Elsevier Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.atmosenv.2007.11.041
dc.sourceScopus
dc.subjectChild care centers (CCC)
dc.subjectCleaning
dc.subjectDeterminants
dc.subjectIndoor air quality (IAQ)
dc.subjectSources
dc.subjectTropics
dc.typeArticle
dc.contributor.departmentBUILDING
dc.description.doi10.1016/j.atmosenv.2007.11.041
dc.description.sourcetitleAtmospheric Environment
dc.description.volume42
dc.description.issue9
dc.description.page2225-2239
dc.description.codenAENVE
dc.identifier.isiut000255620800021
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.