Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.ajo.2004.08.076
Title: Optic disk ovality as an index of tilt and its relationship to myopia and perimetry
Authors: Tay, E.
Foster, P.J.
Aung, T. 
Seah, S.K.
Chew, S.-J.
Chan, S.-P.
Lim, A.T.H.
Issue Date: 2005
Source: Tay, E., Foster, P.J., Aung, T., Seah, S.K., Chew, S.-J., Chan, S.-P., Lim, A.T.H. (2005). Optic disk ovality as an index of tilt and its relationship to myopia and perimetry. American Journal of Ophthalmology 139 (2) : 247-252. ScholarBank@NUS Repository. https://doi.org/10.1016/j.ajo.2004.08.076
Abstract: • Purpose: To examine the association of optic disk ovality with myopic refractive error, axial length, and the visual field. • Design: Prospective observational case series. • Methods: The study included 150 randomly recruited male subjects with myopia. In all cases, one eye was randomly selected, and subjective refraction, slit-lamp examination, applanation tonometry, gonioscopy, A-scan ultrasonography, funduscopy, and color optic disk stereo photography were performed. Disk ovality was assessed using the ratio of minimum to maximum disk diameter (index of tilt). A ratio of ≤ 0.8 was considered as significant disk tilt. Visual fields were tested using static automated threshold perimetry with two methods of optical correction: trial lenses and contact lenses. • Results: Of the total sample, 137 subjects completed the study. Mean age was 21.2 ± 1.1 year, and mean spherical equivalent was -6.36 ± 3.56 diopters. Mean ovality ratio was 0.83 ± 0.09; 55 subjects (40.2%) had significant tilted optic disks. Greater optic disk ovality (tilt) correlated with greater myopia (P = .009) and longer axial length (P = .009); 95.6% of subjects had normal visual fields with both methods of optical correction. Using multiple linear regression analysis, greater tilt was independently related to a higher mean defect on testing with trial lenses (P < .01). • Conclusions: Increased optic disk tilt was associated with higher myopia and reduced sensitivity on field testing. These factors are important in the assessment of glaucoma in patients with myopia. © 2005 by Elsevier Inc. All rights reserved.
Source Title: American Journal of Ophthalmology
URI: http://scholarbank.nus.edu.sg/handle/10635/29156
ISSN: 00029394
DOI: 10.1016/j.ajo.2004.08.076
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

107
checked on Dec 7, 2017

WEB OF SCIENCETM
Citations

94
checked on Nov 23, 2017

Page view(s)

157
checked on Dec 18, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.