Title: Reproducibility of cornea measurements in anterior segment OCT images of normal eyes and eyes with bullous keratopathy analyzed with the Zhongshan Assessment Program
Authors: Chan, J.B.
Yuen, L.H.
Huang, E.H.
Htoon, H.M.
He, M.
Aung, T.
Tan, D.T.
Mehta, J.S. 
Issue Date: Nov-2011
Citation: Chan, J.B., Yuen, L.H., Huang, E.H., Htoon, H.M., He, M., Aung, T., Tan, D.T., Mehta, J.S. (2011-11). Reproducibility of cornea measurements in anterior segment OCT images of normal eyes and eyes with bullous keratopathy analyzed with the Zhongshan Assessment Program. Investigative Ophthalmology and Visual Science 52 (12) : 8884-8890. ScholarBank@NUS Repository. https://doi.org/10.1167/iovs.10-6411
Abstract: Purpose. To determine the interobserver and intraobserver measurement reproducibility of cornea parameters of both normal eyes and eyes with bullous keratopathy (BK) obtained with the Zhongshan Assessment Program (ZAP) on anterior segment optical coherence tomography (AS-OCT) images. Methods. A comparative study was carried out on 24 healthy volunteers and 25 subjects with BK. AS-OCT images were independently analyzed by two examiners. Parameters examined: anterior chamber depth (ACD), central corneal thickness (CCT), posterior corneal curvature (PCC), and posterior corneal arc length (PCAL). Interobserver and intraobserver reproducibility of these parameters was calculated in terms of limits of agreement (mean of differences ± 1.96SD of differences). Results. In the normal group, both horizontal and vertical ACD were successfully measured in 23 of 24 (96%) images. The mean bias for two measurements by two different observers ranged from 0.003 to 0.117 mm for ACD, PCC, and PCAL measurements and from 0.013 to 2.25 μm for CCT measurements, and there were no differences between the two observers (P > 0.05). Mean bias for two measurements by the same grader ranged from 0.005 to 0.327 mm for ACD, PCC, and PCAL measurements and 1.46 to 2.53 μm for CCT measurements. There was no difference between the two observations (P > 0.05). Similar results were found in the BK group. Conclusions. There was high inter- and intraobserver reproducibility for normal and pathologic corneas using the ZAP software. The ZAP software may serve as a new investigatory tool for accurately evaluating the anterior segment and corneal parameters for corneal procedures. © 2011 The Association for Research in Vision and Ophthalmology, Inc.
Source Title: Investigative Ophthalmology and Visual Science
URI: http://scholarbank.nus.edu.sg/handle/10635/110249
ISSN: 01460404
DOI: 10.1167/iovs.10-6411
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.