Please use this identifier to cite or link to this item:
https://doi.org/10.1109/BMEI.2010.5639467
DC Field | Value | |
---|---|---|
dc.title | Feature analysis in slit-lamp image for nuclear cataract diagnosis | |
dc.contributor.author | Li, H. | |
dc.contributor.author | Lim, J.H. | |
dc.contributor.author | Liu, J. | |
dc.contributor.author | Wing, D. | |
dc.contributor.author | Wong, K. | |
dc.contributor.author | Wong, T.Y. | |
dc.date.accessioned | 2014-11-25T09:48:14Z | |
dc.date.available | 2014-11-25T09:48:14Z | |
dc.date.issued | 2010 | |
dc.identifier.citation | Li, H., Lim, J.H., Liu, J., Wing, D., Wong, K., Wong, T.Y. (2010). Feature analysis in slit-lamp image for nuclear cataract diagnosis. Proceedings - 2010 3rd International Conference on Biomedical Engineering and Informatics, BMEI 2010 1 : 253-256. ScholarBank@NUS Repository. https://doi.org/10.1109/BMEI.2010.5639467 | |
dc.identifier.isbn | 9781424464968 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/108610 | |
dc.description.abstract | Nuclear cataract is the most common type of age-related cataract and it is clinically diagnosed using slit-lamp images. Objective measurement of the features in slit-lamp image is investigated using a computerized software system. The correlation between the features and the nuclear cataract grades is analyzed. Experimental results show that intensity of sulcus, color in the lens and nucleus region, intensity of nucleus, and color in posterior reflex region are the key features for grading nuclear cataract. This study of feature analysis can benefit clinical cataract diagnosis and clinical research. The feature analysis can also be utilized to investigate the performance of different graders and be employed in training of new graders. ©2010 IEEE. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/BMEI.2010.5639467 | |
dc.source | Scopus | |
dc.subject | Computer-aided diagnosis | |
dc.subject | Feature analysis | |
dc.subject | Nuclear cataract | |
dc.subject | Slit-lamp image | |
dc.type | Conference Paper | |
dc.contributor.department | OPHTHALMOLOGY | |
dc.description.doi | 10.1109/BMEI.2010.5639467 | |
dc.description.sourcetitle | Proceedings - 2010 3rd International Conference on Biomedical Engineering and Informatics, BMEI 2010 | |
dc.description.volume | 1 | |
dc.description.page | 253-256 | |
dc.identifier.isiut | 000293143500057 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.